ķ
23
Rectifying Faults Yourself
Fault Possible cause Rectification
Does not function
No power supply Check mains power plug
No picture or sound. EURO-AV cable loose Insert plugs at receiver and
TV set
TV set not in AV setting Switch TV set to AV
Aerial is not aligned to a satellite Align aerial to required satellite
(see assembly instructions
for aerial)
Poor aerial cable connections Check cable connections
Defective LNB Replace LNB
Incorrect reception range of LNB Replace LNB
Incorrect LNB oscillator frequency in menu Correct the oscillator frequency setting
(see page 13)
Picture has spikes.
All stations from this satellite Aerial not aligned exactly Align aerial exactly
are disturbed. LNB oscillator frequency is shifted Optimize allocated LNB frequency (see
“Preselecting LNB oscillator frequencies,
page 13).
Satellite blocked by trees, bushes, etc. Remove obstacles or change aerial place.
Dish too small Use the picture and sound improvement
function (see chapter “Using the
Receiver”, page 10).
Aerial cable too long Use Inline amplifier
Cable contacts poor or damp Check contacts
Only on this station Input frequency not tuned in Retune frequency (see “Selecting the
correctly transmission frequency of a station” on
page 12 and “Finetuning the reception fre-
quency for reception unit B” on page 16.
Stations do not correspond to LNB oscillator frequency entered Enter LNB frequency of used LNB
station table. incorrectly optimize if necessary
(see page 13).
Aerial directed at bad satellite. Correct aerial alignment
Remote control does not function Receiver receives no remote control The receiver’s display must be visible,
commands (may be obstructed by an object)
direct the remote control at the receiver.
Batteries empty or polarity reversed Replace batteries or reverse polarity
Universal remote control Remove battery, press any button
programmed incorrectly several times and replace battery. The
basic setting (see chapter on “Universal
Remote Control” on page 6) is automati-
cally set.
Receiver programmed for remote Press the
¢
SA
T 2 key and the
control mode 2 (see page 20) desired function key.
Reception unit B cannot be controlled. Timer active Wait until the Timer has elapsed
or
abort the Timer, see page 18 (internal
Timer) or page 19 (external Timer).