ENGLISH
safety glasses and hearing protection!
Do not wear loose clothing or jewels. Hear, clothing
and gloves must be out of reach of moving parts
as they could get caught by the rotating parts. Do
not use the appliance when barefooted or in open
sandals.
Electrical hazard , keep at least 10 m distance away
from electrical power lines.
During appliance operation, it is necessary to take
a safe and rm posture, especially when steps or a
ladder are being used.
Be careful when going backwards – risk of
tripping!
Do not run! Immediately remove cut
branches/knots from the work area to prevent inju
-
ries. Watch out for falling branches!
Walk! Do not run! As soon as a branch being cut o
starts cracking and falling down, move to the side
immediately and keep safe distance from the falling
wood as it can hurl back up and cause injuries.
Switch the appliance immediately o and remove the
replaceable battery from the appliance when the saw
chain gets blocked. Remove the blocked object.
When working, keep the appliance rmly with both
hands and with a distance from your body.
Make sure the appliance is o before inserting a
battery.
The ON/OFF switch and safety switch must not be
locked.
Before using, check the tightness and proper
seating of all screwed and socket joints and
protective equipment and if all moving parts are
moving smoothly.
It is strictly prohibited to demount, adjust and
alienate the protective equipment on the
machine or put other protective equipment on
the machine.
Do not use the appliance if damaged or the
safety equipment is defective. Replace any worn
and damaged parts.
Do not use the device near ammable liquids or
gases. Risk of re and explosion in case of short
circuit.
Avertissement: Cet outil électrique génère
pendant le fonctionnement un champ magnétique.
Dans certaines circonstances, ce champ peut
perturber le fonctionnement des implants médicaux
actifs ou passifs. An de réduire le risque de blessure
graves ou mortelles, nous recommandons aux
personnes portant un implant médical de consulter
un médecin et le fabricant de l‘implant médical avant
l‘utilisation de l‘appareil.
Battery
Vapours may leak out in case of unauthorised use or
when using a damaged accumulator. Bring fresh air
and seek medical advice if experiencing diculties.
Vapours may irritate the respiratory system.
Risk of re! Risk of explosion!
Never use damaged, defective or deformed accu
-
mulators. Never open or damage the accumulator
or let it fall on the ground.
Never charge the battery in an environment with
acids and easily ammable materials.
Protect the battery against heat and re.
Battery to be used at the ambient temperatures
between 10°C and +40°C only.
Never put the battery on heaters and do not
expose it to strong sunlight for a long time.
After being subject to heavy load, let the battery
cool down rst.
Short circuit - do not bridge the accumulator
contacts with metal parts.
The accumulator must be packaged (plastic bag,
box) or accumulator contacts must be sealed up
for accumulator disposal, transport or storage.
Work instructions
Accumulators are supplied partially charged and
must therefore be fully charged before being used for
the rst time.
Charge the accumulator when the appliance is
running slowly or stops.
A li-ion battery may be charged at any time wit
-
hout any shortening of its life. Charging process
interruption will not damage the accumulator.
A li-ion battery is protected by the Electronic
Cell Protection against deep discharge.
A signicantly shorter operating time of a
charged battery means the battery life is over
and the battery must be replaced.
Original spare batteries to be used only..
Maintenance
Take the replaceable battery from the
appliance before any extension, cleaning
and servicing works.
Repairs and works specied in these Instructions may
only be performed by qualied authorised sta.
Use only original accessories and original spare parts.
Keep the device, in particular the air vents, clean at all
times. Never spray water on the device body!
Never clean the machine and its components with
solvents, ammable or toxic liquids. Us only a damp
cloth making.
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude 255 36 ASL 95728 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info