Safety prevention means:
Touch protection at the device should prevent fire and
burns; no part of the protection can be taken off
permanently.
Full protection is not provided for children and ill
persons!
The heating device is equipped with a low-oxygen
safety device. If a higher concentration of carbon
dioxide (CO2) is detected in the room, the safety
device will automatically shut the appliance off. The
appliance cannot be turned back on until the room is
ventilated properly.
After use of the heating device, the cylinder valve
must be turned off!
Operation
After having read the general safety instructions and
the device-specific safety instructions and having
understood them, you can start operating the device.
Follow these instructions:
Installation of the gas cylinder:
The device uses a mixture of propane and butane
under pressure of 50 mbar.
To operate the device, a gas cylinder with liquid gas
of max. 11 kg of filling is necessary, the hose is pre-
installed.
Gas regulator must be selected and/or purchased first
of all, depending on the purpose of use.
Installation or change of cylinder with liquid gas must
be performed in non-flammable atmosphere.
When the device is not in use and during change
of the cylinder, the device valve must be turned
off.
After the first and before any subsequent putting into
operation and especially after each bottle change, a
leak test using foamy solution (e.g. soapy water) must
be carried out.
Tightness is proven when no bubbles appear.
It is strictly forbidden to check tightness by open
flame!
The cylinder must be placed in such a position so that
it is not in contact with the sheet metal of the burner
and the gas supply attached to it. The hose must not
touch (be in contact with) the hot back side of the
burner.
The device is supplied with a 40 cm long hose. The
hose must not be shortened or exchanged for a
longer one.
Inspect the condition of the hose regularly, at least
during each change of the cylinder.
In case of damage to the hose, it must be replaced
with a hose of the same construction, tested
according to DIN DVGVV.
Connection of the hose to the regulator must be done
with minimum of V4" left thread. The screw spanner
SW 17 is required for installation.
Twisting or distortion of the gas hose during the
installation of the hose and pressure regulator to the
liquid gas cylinder is not permissible.
Warning! The hose must not touch (be in contact
with) the hot back side of the burner!
Operation with pressure regulators other than those
prescribed above is prohibited.
Make sure the hose and regulator are changed after
5 years at the latest.
Connection of the liquid gas cylinder:
Take the protective cover of the valve off.
Take the covering nut from the attachment socket off
by turning (right).
Check the rubber seal in the cylinder valve (regulator
connection).
The regulator and the hose must be screwed on
tightly (left thread). No not use any tool or instrument.
Do not turn the regulator but the sleeve nut.
Check the tightness of the connection.
Change of the liquid gas cylinder:
Close the cylinder valve
Unscrew the regulator.
Screw the closing nut on the connecting tread (left
thread) – put the protective cover on.
Connect the new cylinder and check tightness.
Start up procedure / discontinuation or stopping procedure of
the catalytic stove:
Before operation, let the cylinder stand in a vertical
position for 1 hour if transported so the elements
more burdening to the environment may settle down
to the bottom of the cylinder.
Place the gas cylinder to the inner space of the
device (back side). Connect the gas cylinder as
described above.
Open the cylinder valve on the propane cylinder by
turning to the left.
Push the large setup button down and turn it to the
large flame symbol – start.
Push the piezo-ignition button several times, to light
the starting flame. When the starting flame is visible,
keep the setup button pushed for about 20 seconds,
heating up the thermal element. You can release the
setup button afterwards and the heating is turned on
to the highest level. If the starting flame goes off,
though, repeat the procedure.
The heating output can be lowered by pushing lightly
on the setup button and turning it to the medium or
minimum flame symbol. We recommend to wait for 10
minutes after starting the operation before changing
the heating output.
The catalytic gas plate is slightly hot only in the area
of the starting flame, but the full heating output is
spread over the whole catalytic plate.
The slight smoke (fresh paint) will dissipate after
heating up.
CAREFUL! Do not move when hot (transport).
The gas cylinder must not be turned during the
operation or shut down of heating device. The highest
danger of accident!
Shutting off of the catalytic gas heating device:
CLOSE THE GAS VALVE ON THE CYLINDER.
Servicing
Do you have any technical questions? A claim? Do you
need spare parts or the Operating Instructions?
You will be helped quickly and without needless
bureaucracy at our webpage www.guede.com in the
Service part. Please help us be able to assist you. To be
able to identify your appliance when claimed, we need to
know its serial No., order No. and year of production. All
these details can be found on the type label. Enter the
details below for future reference.
Serial No.:
Order No.:
Year of production:
Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com
12
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

gude-blueflame-4200-b-85079

Suche zurücksetzen

  • wenn ich nach dem starten den aufgedrehten gasregler auf normale flamme einstellen möchte, geht der ofen immer aus. woran kann das liegen? Eingereicht am 24-11-2019 09:25

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude Blueflame 4200 B 85079 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info