GB
VENTILATION
WARNING: Follow the minimum fresh, outside air
ventilation requirements. If proper fresh, outside air
ventilation is not provided, carbon monoxide poisoning
can occur. Provide proper fresh, outside air ventilation
before running heater.
Provide a fresh air opening of at least 2800 square cm (three
square feet) for each 29kw (100,000 Btu/Hr) rating. Provide
extra fresh air if more heaters are being used..
Example: A 44kw (150,000 Btu/Hr) heater requires one of the
following:
• a two-car garage door [4.9 meter (16 feet) opening] raised 9
cm (3.5 inches).
• a single-car garage door [2.75 meter (9 feet) opening] raised
15.25 cm (6 inches).
• two, 76 cm (30 inch) windows raised 28 cm (11 inches).
THEORY OF OPERATION
The Fuel System: The air pump forces air through the air line.
The air is then pushed through the burner head nozzle. This air
causes fuel to lift from the tank. A ne mist of fuel is sprayed into
the combustion chamber.
The Air System: The motor turns the fan. The fan pushes air
into and around the combustion chamber. This air is heated and
provides a stream of clean, hot air.
The Ignition System: The ignition control assembly provides
power to the ignitor. This ignites the fuel/air mixture in the
combustion chamber.
The Flame-Out Control System: This system causes the
heater to shut down if the ame goes out.
(see gure 4)
A. Clean Heated Air Out, B. Combustion Chamber, C. Ignitor, D.
Fan, E. Motor, F. Air Pump, G. Air Intake Filter, H. Cool Air In,
I. Air Output Filter, L. Ignition Control Assembly, M. Air Line To
Burner, N. Fuel Filter, O. Nozzle, P. Fuel Tank, Q. Air For Fuel
System, R. Air For Combustion And Heating, S. Fuel.
OPERATION
WARNING: Review and understand the warnings in the
Safety Information section, page 2. They are needed to
safely operate this heater. Follow all local codes when
using this heater.
TO START HEATER
1. Follow all ventilation and safety information.
2. Fill fuel tank with kerosene or No. 1 fuel oil.
3. Attach fuel cap.
4.Plug power cord of heater into standard 220-240V/50 Hz,
grounded (earthed) outlet. Use an extension cord if needed.
Use only a three-prong, grounded (earthed) extension cord.
Extension cord wire size requirements:
Up to 30 meters (100 feet) long, use 1.0 mm2 (16 AWG)
conductor.
30 to 61 meters (101 to 200 feet) long, use1.5 mm2 (14 AWG)
conductor.
Push ON/OFF switch to ON (|) position and heater should start
in 5 seconds. If heater does not start, see Troubleshooting (page
7).
TO STOP HEATER
Push ON/OFF switch to OFF (O) position.
TO RESET HEATER
1. Push ON/OFF switch to OFF (O) position and wait 10 seconds
(2 minutes if heater has been running).
2.Repeat steps under To Start Heater.
(see gure 5 e 6)
A. ON/OFF Switch with Light.
STORING,TRANSPORTING, OR
SHIPPING
Note: If shipping, transport companies require fuel tanks to be
empty.
1. Drain fuel tank.
Note: Some models have drain plug on underside of fuel tank.
If so, remove drain plug to drain all fuel. If heater does not
have drain plug, drain fuel through fuel cap opening. Be sure
all fuel is removed.
2. Replace drain plug if provided.
A.
B.
C.
D.
E.
F.
G.
H.
L.
I.
N.
M.
O.
P.
S.
R.
Q.
Figure 4 – Cross Section operational view.
|
O
|
O
A.
Figure 5-6 – ON/OFF Switch, Models 10 KW, 20 KW, 29 KW
and 44 KW.
VENTILATION
THEORY OF OPERATION
OPERATION
STORING,TRANSPORTING, OR SHIPPING
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude GD30IE 85091 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info