ENGLISH
Technical Data
Gas Turbine GGH 10 L
Art. No ................................................................................................................................................................................................85112
Service connection ..................................................................................................................................................230 V~50 Hz
Max. Power .................................................................................................................................................. 10 kW (8600 kcal./h)
working pressure ...........................................................................................................................................................700 mbar
Type of gas .........................................................................................................................................................Propane/butane
consumption .............................................................................................................................................................ca. 0,73 kg/h
Fan power ..........................................................................................................................................................................320 m/h
Weight .......................................................................................................................................................................................4,7 kg
Read and understand the operating instructions
before using the appliance. Abide by all the safety
measures stated in the service manual. Act responsib-
ly toward third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Specied Conditions Of Use
For heating and drying in construction, agriculture and
storage areas (for ventilated spaces only). Not suitable for
enclosed spaces. For propane and butane gas.
Do not use this product in any other way as stated for
normal use. Respecting technical data and safety pre
-
cautions.Not observing general regulations in force
and instructions from this manual does not make the
manufacturer liable for damages.
The gas heater must not be used:
For heating of closed or occupied rooms (resi
-
dential buildings) or operation in these areas;
In the vicinity of combustible materials (e.g.
paper, building materials);
An explosive atmosphere may be created in
places where volatile materials (e.g. gasoline,
solvents, chemicals) are stored or present;
After an arbitrary structural change in the gas
heater;
In case of wrong, unauthorised connection to
a gas source
In places that are not suciently ventilated.
As a source of heat for events and festivals.
Power tool description
1. Handle
2. Protective grille
3. Piezzo
4. fan switch
5. Gas valve knob
6. gas hose
7. Reducer
Emergency procedure
Conduct a rst-aid procedure adequate to the injury
and summon qualied medical attendance as quickly
as possible. Protect the injured person from further
harm and calm them down. For the sake of eventual
accident, inaccordance with DIN13164, a workplace
has to be ttedwith a rst-aid kit. It isessential to
replace any usedmaterial in the rst-aid kitimmedia-
tely after it has been used.
If you seek help,state the following pieces ofinfor-
mation:
1. Accident site
2. Accident type
3. Number of injured persons
4. Injury type(s)
Requirements for operating sta
The operating sta must carefully read the Opera-
tingInstructions before using the appliance.
Qualication:Apart from the detailed instructions by
aprofessional, no special qualication is necessary
forappliance using.
Minimum age:Persons over 16 years of age can
only workon the appliance.An exception includes
youngsters trained in order to reachknowledge
under supervision of the trainer duringoccupational
education.
Training:Using the appliance only requires corre
-
spondingtraining by a professional or the Operating
Instructions. Nospecial training is necessary.
The operator is responsible for accidents or risks to third
parties.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude GGH 10 L 85112 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info