GP 600 VF P | GP 1100VF | HWA 800 VF P | HWA 1100 VF | HWW 600 VF P | HWW 1100 VF | HWW 1400 VF / INOX
ENGLISH
GB
Read and understand the opera-
ting instructions before using the
appliance. Abide by all the safety
measures stated in the service manual. Act responsib-
ly toward third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Specied Conditions Of Use
The pump is designed for pumping clean water only
to supply the home with water and to use it at home,
in garden, courtyard and for elds. Respecting techni-
cal data and safety precautions.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
When used in this manner, its service life is curtailed
correspondingly. In these cases, then, use a time
switch to secure sucient idle periods between
cycles of operation.
Do not leave the pump unattended while in
operation in order to prevent subsequent
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the
existing water-supply network as a pressure-
boosting device.
Never use the pump as a pool circulation
pump.
Safety Instructions
WARNING!
Electric shock! There is a risk of an injury caused
by electric shock!
This device is not intended for use by persons (inclu-
ding children) with limited physical, sensory or mental
capabilities or without the necessary lack experience
or knowledge unless they are supervised by a person
who is responsible for their safety or were instructed
by that person in how to use the device.
Children should be supervised to ensure that they do
not play with the device. Always keep children and
unauthorised persons out of reach of the appliance.
Operation is only allowed with a safety switch
against stray current (RCD max. stray current of
30mA).
Before putting into operation, a qualied electrician
must check whether electric safety measures required
are in place. Any national regulations in this regard
must be complied with.
Electric connection to a socket.
Do not expose the appliance to rain and do not use it
in wet or moisture conditions.
It is necessary to make sure the connecting socket
was not near water and humidity and the plug was
protected against humidity.
Avoid installing the appliance in wet shafts (risk of
short circuit, corrosion eects)!
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Only use splash proof extension cables approved for
outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or
carry it while it is connected to the grid!
Check the cable and/or socket for damages before
the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must
be replaced by the manufacturer. Do not under any
circumstances attempt any repair yourself.
Protect the feeder cable from excessive temperatures,
oil and sharp edges.
If the pump is in operation, neither people nor
animals can be present or plunged in the pumped
liquid (e.g. pools, cellars, etc.).
The pump must not in any case run without
llings.
Do not leave the pump unattended while in operati-
on in order to prevent subsequent damages caused
by eventual malfunctions. Make sure to disconnect
the device from the grid if you do not plan on using it.
The temperature of the drained liquid must not
exceed +35 °C.
When using the pump for domestic water supply,
alwaysobserve the local regulations of water manage-
mentauthorities and the waste water drainage.
If the pump is used in ponds, wells, etc. and appropri-
ate pumping stations, standards valid for pumps in
the given country must unconditionally be observed.
23

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude HWA 800 VFP 06030 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info