628468
9
Zoom out
Zoom in
Vorherige Seite
1/48
Nächste Seite
Please read carefully these Operating Instructions before putting the appliance into operation.
A.V. 2 Any reprints, even partial, are subject to approval. Technical changes reserved. Pictures just for illustration purposes!
Do you have any technical questions? A claim? Do you need spare parts or the Operating Instructions?
You w ill be helped quickly and w ithout needless bureaucracy at our w ebpage www.guede.com in the Services part. Please help us
be able to assist you. To be able to identify your appliance w hen claimed, w e need to know its serial No., order No. and year of
production. All these details can be found on the type label. Enter the details below for future reference.
Serial No. Order No. Year of production:
Tel.:
Fax:
E-Mail:
Supply includes plus appliance description (pic. A)
1. Pump connection
2. Suction connection
3. Pressure hose
4. ON/OFF
5. Tank feet
6. Tank
7. Air valve
8. Air gauge
9. Pump body
10. Bleeder screw
11. Drain screw
Warranty
A w arranty period of 12 months applies to commercial use
and 24 months apply to private use and commences on the
day of purchase of the device.
Warranty applies exclusively to failures due to defective
material or w orkmanship. An original sale slip w ith indication
of date of sale must be presented in case of claiming for the
w arranty rights.
Warranty does not cover unprofessional use such as device
overload, violent use, damage caused by third party or foreign
materials, failure to comply w ith operations and assembly
manual, and normal w ear and tear.
General safety instructions
PLEASE FOLLOW CAREFULLY THESE INSTRUCTIONS
TO GUARANTEE A HIGH SAFETY LEVEL:
The pump is not appropriate to be operated for a
long time (e.g. as a circulating pump in ponds or stream
flows). If used in this manner, the service life is
shortened accordingly. In such a case, use a timer and
provide long breaks between individual operating cycles.
The pump must not be connected to the existing
water supply system as an appliance increasing pressure.
The pump is not appropriate as a long-term,
automatic protection against overflow of tanks and wells
or to control underground water in cellars.
Do not leave the pump unattended to prevent
damage as a result of any wrong function. The pump
must necessarily be unplugged when not used.
Caution: Operation is only allowed with a safety
switch against stray current (max. stray current of 30m A
pursuant to VDE regulation part 702). Please contact your
electrician.
Caution: The pump must not in any case be operated
without any charge filling.
The user is responsible to any third party as far as using
the pump (pumping station, etc.) is concerned.
To be used on connections w ith a safety sw itch against
stray current only (FI)!
Before putting the unit in operation, a skilled electrician
should check w hether the required electrical safety
devices are available.
Electrical connection w iring should be done via a socket.
Check the voltage. Technical details on the plate should
conform to the line voltage.
If the pump is used in ponds, w ells etc. and related pumping
stations, the standards of the use of pumps in respective
countries apply.
The pumps used outdoors (e.g. in ponds, etc.) must be
fitted w ith a rubber connection cable, H07RNF type,
according to DIN 57282 or DIN 57245 standards.
If the pump is being operated, no person or animal
must stay or plunge in the water to be pumped (e.g.,
pools, cellars, etc.).
The temperature of the pumped liquid must not exceed
+35 °C. If an extension cable is used, it must exclusively
be out of rubber, H07RNF type, according to DIN 57282
or DIN 57245 standards. Never touch, lift or carry the
pump by cable w hen plugged. It is necessary to make
sure the connection socket is in a distance from w ater
and moisture and the plug is protected against moisture.
Before putting the pump into operation, check w hether
the electric cable and/or outlet
are not damaged.
Unplug the appliance before any w ork on the pump.
If the pump is defective, repair must only be provided
by an authorized service centre. Original spare parts to
be used only.
Please note that according to the standards in force
we will not assume any liability for damage incurred
by our appliances in the following cases:
Unauthorised repairs executed by unauthorised
service centres;
Use in conflict to the designation or failure to use
the appliance as designated;
Pump overloading by continuous operation;
Damages as a result of icing and other defects
caused by climatic influences;
The same regulations w ill apply to accessories.
An electrician must necessarily be
contacted if the feeder cable is damaged. Do
not execute any repair with your own hands in
any case.
This appliance has not been designed
to be used by persons (including children)
with physical, sensory or mental limitation.
Persons lacking experience in or knowledge
of the appliance must also not work with the
appliance.
9
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude HWW 1000 P INOX 06026 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info