Important: Should the pump be out of operation for a longer period of time, the pipeline and the pump shell must be
unconditionally emptied.
Troubleshooting
CAUTION: FIRST OF ALL CHECK ALWAYS THE FUSES AGAINST OVERLOADING!
Failure Cause How to remove the failure
Engine cannot be
started.
No nework voltage.
Pump wheeel is blocked.
Check the voltage.
Turn the engine shaft with screwdriver through the fan
cover (to release friction circles sealing that may be
stuck together)
The pump does not
suck
Missing, untight or blocked foot valve
Foot valve is not in water.
No water in the pump shell.
Too high suction height.
Air bubbles in suction pipeline.
Connections not sealed, the pump sucks the air,
the pump is not bleeded.
Assembly or clean the foot valve.
Immerse the foot valve into water.
Fill the pump shell with water.
Check the suction height.
Check the tighting of suction pipeline.
Carefully repeat connection according to chapter
„Putting into Operation“!
Insufficient quantity of
water to be repumped.
Too high suction height.
Foot valve suction basked dirty
Water level drops quickly.
Check the suction height.
Clean tne suction basket.
Locate the foot valve lower.
Clean the pump and replace worn parts.
Thermoswitch
switches the pump off.
Pump if overheated and switched off by the
thermal overloading protection.
Electric power missing.
Impurity particles (e.g. pebbles) have settled
down in the suction hole.
Let the device getting cool!
Disassamble and clean the pump, prevent suction of
foreign substances.
Inspection and Maintenance
With the exception of the below described cases, the pump shall be repaired in customer´s service.
Check the air pressure in the filling valve vessel (under the black lid) regularly (every 3 months) by means of a separate
device for pumping the tyres with manometer, as described below.
Pull out the network plug.
Open the appliance, watermain tap etc.
Modify the air pressure with separate device for pumping the tyres to 1,5 ± 0,3 bar.
Safety Instructions for Inspection and Maintenance
Before any maintenance works the connection with electric network shall be interrupted (by pulling the plug out of the
socket) and checked if the pump is not being put into operation.
Only device on which the maintenance is performed regularly and that is properly cared for can be good helper.
Defaults in maintenance and care for device can cause unpredictable accidents and injuries.
Plan of Inspection and Maintenance
Time interval Description Further details, if any
3 months Check the air pressure in the vessel 1,5 ± 0,3 bar
According to the need
and the contamination
level
Clean the foot valve.
Check the foot valve function
(D)
33

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude HWW 1200 2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info