Indirect
electric
contact
Electric shock
via the medium
Insufficient current sw itch FI
Disposal
The instruction for disposal are to be found in pictograms
located on the device and/or on the packing. The explanation
of individual terms can be found in Chapter Marking on the
Device”.
The Requirements on the Operator
The Operator shall carefully read the Operation Manual
before using the device.
Qualification
The professionaly versed person does not need any special
qualification for using the device.
Minimum Age
The devfice may only be operated by persons at the age of
16 and more.
The exception is using the device by an adolescent in the
course of his training for the profession, w here the device is
used for the purpose of getting the skill under supervision of
the instructor.
Training
The operator w ho is going to operate the device w ill only
need to get corresponding training by a professionally versed,
and/or a training according to the Operation Manual. No
special training is necessary.
Technical data
JA 200 M 230 V
Supply main
230 V / 50 Hz
Engine P1 output
2000 W (P1)
Max. suction height
9 m
Max. pumped quantity
5000 ltr./h
Max. pumping height
50 m
Pressure supply main
1“
Suction supply main
1“
Way of protection
IP 44
Water temperature
35°C
L
WA
74 dB
Weight approx.
25 kg
Assortment position No.
94197
Transport and Storing
When storing in winter, make sure that no water is in
the device, otherwise the device may be destroyed due to
freezing.
Assembly and First Putting into Operation
Filter and Screen for Impurities
If the w ater contains sand, the pump shall be operated w ith
the filter for impurities (available as accessory) located on the
suction supply main of the pump. Should the sand penetrate
into the friction circle sealing (connecting shift pump) the
sealing w ould be destroyed. If this occurs in the course of
guarantee term, it w ill be qualified as a fault caused by the
user and this case w ill be excluded from any provision of
guarantee.
Safety Instructions for First Putting into Operation
Caution: The pump shall never be operated
without water.
When using the pump (w ater equipment) the user is
responsible to third persons
The user may operate the pump only on connecting lines
furnished with the insufficient current switch (FI switch)!
Before putting into operation the authorized electrician should
check if there are required electric safety measures available.
The electric connection shall be performed by means of a
socket.
Voltage examination. Technical data on the label shall comply
w ith the electric netw ork voltage.
If the pump is used for ponds, w ells etc. and in corresponding
w ater equipments, the standards applicable in the countries
w here the pump is used shall be unconditionally observed.
Electric pumps used outside (e.g. at the ponds etc.) shall be
furnished w ith rubber electric cable type H07RNF, according to
standard DIN 57282 or. DIN 57245.
When the pump is in operation, no people or animals are
allowed to stay or dive in the liquid being repumped (e.g.
in swimming pools, in cellars etc.).
The repumped liquid temperature shall not exceed +35 °C.
Should extension cables be used, they shall be made
exclusively of rubber, type H07RNF, according to standard
DIN 57282 or DIN 57245. The pump connected to the
electric netw ork shall never be touched by a cable, never
lifted by holding the cable or transport by means of a cable.
The connecting socket shall alw ays be in necessary
distance from w ater and moisture and the plug shall be
protected against moisture.
Before putting the pump into operation check if the electric
cable and/or the socket are not damaged.
Before performance of any w orks on the pump the plug
shall be pulled out of the socket..
If the pump is built-in in a gully, the gully shall be covered
w ith cover to ensure the safety of people w alking there.
The pump shall never be installed in moist shifts
(danger of shortcut, damage caused by corrosion)!
For avoiding or prevention of possible damage (as e.g.
flooding the rooms etc.) due to faulty pump operation
(e.g. due failure or defects) the owner (user) shall take
reasonable safety measures (installation of alarm
equipment, a spare pump etc.)
In case of failure on the pump,. the repair shall be
performed exclusively by an authorized service
repairshop.Only original spare parts may be used.
We have to draw your attention to the fact that
according to the valid standards we cannot take
responsibility for below mentioned cases of possible
damage caused by our devices:
Unproper repairs performed by unauthorized service repair
shops;
Using pump for a different purpose or failing to observe its
use according to the provisions;
Overloading of the pump by long-term operation;
Protection against Thermal Overloading
A sensor is built into the engine that automatically sw itches
off the pump if a certain temperature has been exceeded,
and/or it sw itches the pump on after it has been cooled. This
increases the service life of the pump quadruptly, and
prevents burning of the electric engine.
Protection against Overloading /Thermoswitch of the
Engine
The pump is furnished w ith an engine thermosw itch. If the
motor is overheated, the thermosw itch sw itches the pump
automatically off. The cooling period makes approx. 25
minutes, thenafter the pump w ill be automatically sw itched
on again. If the engine sw itch is on, it is necessary to find
and remove the cause (see also “Troubleshooting”). The
data here given cannot be considered as instructions for
home made” repairs, because the repair w orks require
specific professional know ledge and skill.
10
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude JA 200 M 230 V 94197 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info