1 Unit
1.1 Scope of Delivery
Fig. 2
MP 120/5A/GJ (# 94188)
Ideal to irrigate gardens, irrigation equipment
operation, pumping water from ponds, water
streams, tanks, wells, flooded cellars etc.
.
1. Pump connection
2. Bleed screw /Filler neck
3. Suction connection
4. Drain screw
5. Foot
6. On/Off switch
7. Connecting cable
8. Pump body
9. Carrying handle
10. Motor casing
1.2 Warranty
A warranty period of 12 months applies to commercial use and 24 months apply to private use and commences on the day of
purchase of the device.
Warranty applies exclusively to failures due to defective material or workmanship. An original sale slip with indication of date of
sale must be presented in case of claiming for the warranty rights.
Warranty does not cover unprofessional use such as device overload, violent use, damage caused by third party or foreign
materials, failure to comply with operations and assembly manual, and normal wear and tear.
2 General Safety Instructions
Prior to the initial use of the unit, the operating instructions should be read completely. If in doubt with regard to connection and
operation of the unit, consult the manufacturer (servicing department).
FOLLOW THE INSTRUCTIONS BELOW CAREFULLY IN ORDER TO SECURE A HIGH DEGREE OF SAFETY:
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the
appliance.
Caution: Always operate with FI (stray current protection switch)!
The pump should never be operated as a swimming pool circulating pump
The pump has not got any feed cable and is allowed to be connected by a professional electrician only.
The pump should not be used in swimming pools. Only professional is allowed to do the electric installation.
The pump hould be fed via stray current protection switch dimensioned at 30 mA max.
Do not let the pump dry-run without any water supplied. It would threaten the service life of the pump and damage the
motor.
Never wrap the pump head in a blanket or a cloth in an attempt to prevent the water getting frozen in a cold weather.
Never use the pump at the outdoor temperature above 40°C or below 0°C and with water at the temperature above 35 °C.
Take care no to use the pump with fluids other than water
Avoid water with sand, it may damage the sealing.
Read instruction for operation carefully before assembly and putting in operations and follow the instructions with care.
Persons not familiar with the pump operation are recommended to read the operation and maintenance manual thoroughly
prior to putting
the unit in operation so that the risk of damaging it is avoided.
The user is to be held liable to third persons while at the workplace
The pump should not be put in operation unless equipped with a cable or a rubber-coated extension cable type H07RNF,
subject
to standards DIN 57282 or DIN 57245.
The pump should not be lifted, fixed or moved by connecting electric cable
You should make sure that the plug connections are protected from the moisture and possible floods.
Check to see that the connecting cable and the plug are in good order before the use. Place the pump on a flat, stable,
horizontal
base.
10
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude MP 120-5A-GJ 9418 8 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info