621532
13
Zoom out
Zoom in
Vorherige Seite
1/57
Nächste Seite
This device corresponds to all appropriate safety
regulations. Repairs may only be executed by
qualified electricians in authorised service repair
centres while using original spare parts. Failing to
observe this regulation may lead to an accident.
Emergency Action
Apply the first aid adequate to the injury and get qualified
medical assistance as quickly as possible. Protect the
injured person from more accidents and calm him/her
down.
For the sake of eventual accident, in accordance with
DIN 13164, a workplace has to be fitted with a first-aid
kit. It is essential to replace any used material in the
first-aid kit immediately after it has been used. If you
seek help, state the following pieces of information:
1. Accident site
2. Accident type
3. Number of injured persons
4. Injury type(s)
Using the appliance as designated
The compressor has exclusively been designed for the
production and accumulation of compressed air.
The compressed air is only suitable for pneumatic tools
/appliances/ of a machine. Any other use is conflict with
the compressor designation.
Residual Dangers
Direct electric contact
A faulty cable or faulty connector plug may lead to a
fatal accident caused by electric current.
Have always the faulty cables and connector plugs
replaced at a specialist. Use the device at a connector
equipped with current protector (RCD) only.
Indirect electric contact
Injury by parts of the machine that are live or by
faulty constructional elements of the machine.
Always pull the connector plug out of socket at
maintenance works. Operate with current protector only.
Insufficient local lighting
Insufficient lighting represents a high safety risk.
Always ensure sufficient lighting at work with this device.
Disposal
Instructions for disposal result from icons on the device,
or more precisely, on the package. Description of each
meaning can be found in the “Marking“ chapter.
Operating Staff Requirements
The operating staff must thoroughly read the operating
instructions before using the machine.
Qualification
No additional qualification is needed for using the device
apart from detailed training by a person with expert
knowledge.
Minimum Age
The device may only be operated by persons that have
reached 16 years of age.
An exception includes device use by juveniles within job
preparation for purpose of reaching skills under
instructor's supervision.
Training
Appropriate training is only needed for device use. No special
training is necessary.
Transportation and Storage
If the device is stored for a longer period of time it needs to
be thoroughly cleaned and stored so that it was not
accessible to unauthorised persons.
The compressor must never be stored or transported laying
or under pressure!
Pressure in the air jet may be reduced at compressed air
cooling.
Assembly / First Putting into Operation
If the compressor is supplied without wheels assemble it with a
screw wrench according to pic. 2. The sequence of screws, nuts
and washers is evident from pic. 2. In case of need, a rubber foot
also needs to be screwed on. Jointing materials, such as screws,
nuts, etc. are included in the supply.
Visser le filtre à air sur les deux côtés dans le thread approprié
(12).
Transport stopper of the oil tank needs to be exchanged for
throat for oil adding and correct oil level needs to be ensured
(see the "Handling Throat for Oil Adding and Oil Level
Inspection" chapter) before putting the compressor into
operation)
Check the oil level at every startup (pic. 3).
Handling
The compressor may be put into operation after reading and
understanding the general safety instructions and safety
instructions. Proceed as follows:
Switching the appliance on
Connect the compressor power cord to the electrical
network.
Pull the switch (1) up.
The compressor is fitted with an automatic pressure switch
that switches the compressor off after reaching the upper
operating pressure and switches it automatically on again
when air is needed again. Switching pressure 6 bar, max.
pressure 8 bar.
Operating pressure control
The operating pressure can be set in an easy way. If turning
the knob (2) in the + direction, the operating pressure
increases. If turning in the – direction, the operating pressure
decreases. The operating pressure can be fixed by
tightening the lock ring.
The compressor is fitted with an automatic safety valve that
releases pressure in case of overpressure. The air nozzle
can be depressurized manually by pulling the ring on the
valve (10).
Switching the appliance off
The compressor must always be switched off by the switch
(1) and when you do not intend to use the appliance then
disconnect it from mains.
Remove the transport oil peg, add oil to the neck and make sure
there is appropriate oil level, using the oil gauge included in the
supply.
The filter insert should be cleaned from time to time. Remove the
foam filter. It can be cleaned by warm soap water solution. Dry
the foam filter and refit it.
13
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude SET 380-10-50 KR 15 TLG - 71175 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info