624753
16
Zoom out
Zoom in
Vorherige Seite
1/152
Nächste Seite
GB
16
safe and perfect. Mind the correct adjustment
and setting of moving parts. Do some
elements fail to fit correctly in the others? Are
some of them damaged? Is everything
installed properly? Are any other conditions
of the unit perfect functioning met? Any
damaged protective devices etc. have to be
repaired or replaced by authorised
serviceman, unless otherwise stated in the
operating manual. Have the defective
switches replaced in an authorised
workshop. If a repair of the unit has to be
provided, consult a nearest servicing centre.
.Switch the motor off, before adjustment and
maintenance. That applies particularly for
replacement of the rotary blade. Always pull
out the ignition plug socket during works of
the type.
Take precautions to prevent electrical
shock. Avoid body contact with earthed
surfaces, such as water pipes, heater,
cookers and fridges.
Use approved parts only. Use genuine
spare parts for maintenance and repairs y.
Contact an authorised servicing centre for
the purpose. .
Warning! Use of any accessories and parts
not expressly recommended in this manual
may result in a risk for persons and material.
Caution: Use a sliding guide rod at any
work. .
Initial Operation Safety
Instructions
Unplug the tool before adjustment and
maintenance. .
Caution Rotating blade may severely
injure hands or cut the fingers off.
Never work without blade protection
cover.
Before using the tool for the first time, check
to see that the data on the plate coincide with
the mains characteristics. .
If an extension cable is used, make sure that
the wire is sufficient for the stated input.
Diameter 1.0 mm
2
. as a minimum.
Keep the bench and the entire work area
clean. Remove the sawdust and articles not
necessary any more. .
Look out for the places where a risk of
tripping is imminent, e.g. supply cable.
The person working with the unit should not
be distracted if possible. .
Mind the motor and saw blade rotation
direction.
After the motor is witched off, the blade
should not be held back with lateral force.
Use only blades that are in perfect condition,
i.e. sharpened, without any cracks, fissures,
deformations etc. Defective blades have to
be replaced immediately.
Make sure to see that the arrow ob the blade
points to the same direction as that on the
tool. .
Protection equipment on the tool should not
be removed or put out of the operation.
Damaged or defective protection facilities
have to be replaced immediately.
If you are interrupted by a person during the
work with the saw. Always finish the job you
are doing before you look elsewhere.
Your product should always be placed on the
unit table. Never use the tool so that the work
to be cut is outside the table. .
Be sure that your hands are laid safely at any
time that is they cannot slide down and get in
the contact with the saw.
If you work with a long piece, use additional
supports or a pas for the saw not to get
jammed.
The part of the piece that is to be cut off
should be in any case free of any nails and
similar foreign objects. Always stand
alongside of the blade.
Never overload the machine, it will run more
slowly and will get overheated.
Never cut several pieces at a time.
Always used a sliding guide rod. .
Do not attempt at removing chips, pieces of
wood or a jammed piece without putting the
tool off and unplugging it
Always switch the tool off and unplug it to
remove any defects or the pieces to be
worked.
Adjustment, measurement, cleaning etc. may
be done only with the motor switched off and
the plug pulled of the outlet.
Do not leave the work area unattended
without the motor being switched off and the
plug pulled put.
Any safety and protection devices should be
fitted back correctly after their maintenance
and repair having been completed.
It is unconditional to be aware of the safety
regulations effective on the site and of all the
other regulations of general need.
The tool should be used only in combination
with a suitable extracting system.
This bench, trimming and mitre cut saw has
to be connected to the mains of 230 V and
16 A.
Use the power cable for the assigned
purpose only.
Mind safe footing and hold the balance while
working.
Safety equipment should be always checked
up before using the unit. Make sure that even
slightly damaged parts are able to work
properly.
Check any movable parts for perfect
functioning. Be particularly careful about
damaged and sticking ones. The parts have
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude TKGS 1800 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info