MAGYS 400-4 / 400 GR / 500 GR / 500 WS
EN
REEL AND TORCH ASSEMBLY (FIG. 3)
Position the reel on to the support taking care of the pin (1). To use with 5kg (Ø200mm) wire reels requires use of
reel adaptor (ref. 042889).
• Adjust the reel break (2) to avoid the reel movement tangling the wire when welding stops. Then tighten the plastic
screw (3) rmly.
• For the rst use :
- Release the xing screw of the wire guide (5)
- Place the rollers, and tighten the screws (6).
- Place the wire guide (7) as close as possible to the roller but without touching it, then tighten the xing screw.
To select the adjustment of the drive rollers (8), bend the wire where it comes out of the nozzle to stop it, and then
start the motor. Tighten the knob whilst pressing the trigger until the wire starts to move. The setting is correct when
the guide roller slides over the wire, even when it is blocked at the end of the torch.
NOTE: When the trigger is pulled and without any contact detected within 4s, the MAGYS will automatically switch to
the ‘fast forward’ mode until the trigger is released. There is no gas during this operation.
WARNING: The ‘fast forward’ mode use current in the wire; avoid any contact with any metallic part around.
GAS COUPLING
Fit the regulator/owmeter to the gas bottle, and then t the gas pipe to the connector (see (10), FIG-2 for MAGYS
400-4). To avoid gas leaks, use the collars provided in the accessories box.
LIQUID COOLING (MAGYS 500 WS) (FIG-2) & THERMAL PROTECTION
Connect the red and blue wire of the connecting harness from the generator (11) to the separate wire feeder (see WS-
4L/W5S-4L user manual)
Fill the tank (12) up to its maximum (5,5L). The CORAGARD CS330 cooling liquid (or equivalent), recommended
by GYS, must be used (more information in the website: www.aqua-concept-gmbh.eu). The use of any other cooling
liquid, and especially the standard automobile liquid, can lead by electrolysis effect, to the accumulation of dumps in the
cooling system, damaging it and even more by blocking the circuit.
Any damage caused to the machine by the use of another cooling liquid will not be taken under warranty.
The MAGYS 500 WS is not recommended to be used by an air cooled torch.
If anyway you want to use an air cooled torch, a by-pass is supplied with the unit. Connect it between
the red and blue cables. If you don’t respect this rule, the pump will be damaged, and the repair will not
be taken under warranty.
MAGYS 500 WS: NEVER USE YOUR UNIT WITHOUT COOLING LIQUID
when the pump is working. Ensure liquid is at least minimum level (gauge at back of machine)
Failure to adhere to this may result in irreparable damage to the cooling system, and machine.
• Always respect the basic rules of welding.
• Do not block/cover the ventilation holes of the machine.
• Leave the device plugged in after welding to allow proper cooling down.
• Thermal protection: The LED(8) switches on when the unit is on safety mode. The cooling time (forced ventilation) is
by cycle of 10 minutes for the 400-4 and 20 minutes (forced ventilation + pump) for the MAGYS 400 GR/500 GR/500
WS depending on the external temperature.
• Ventilation: the fan is only active during the welding and the cooling cycles.
DUTY CYCLE & WELDING ENVIRONMENT IN USE
• The welding unit describes an output characteristic of "constant current" type. The duty cycles following the standard
EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table below:
X / 60974-1 @ 40°C (T cycle = 10 min) I max 60% (T cycle = 10 min) 100% (T cycle = 10 min)
Magys 400-4 / 400 GR 50% @ 350 A 320 A 260 A
Magys 500 GR / 500 WS 50% @ 450 A 410 A 320 A
Note : The machines’ duty cycle has been tested at room temperature (40°C) and has been determined by simulation.
• These are Class-A devices. They are designed to be used in an industrial or professional environment. In a different en-
vironment, it can be difcult to ensure electromagnetic compatibility, due to conducted disturbances as well as radiation.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gys MAGYS 400 GR wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info