SYMPTOMS POSSIBLE CAUSES REMEDIES
No welding current
Bad connection to the main supply.
See the branch connection and look if the plug is fed by
3 phases.
Bad earth connection.
Control the earth cable (connection and clamp
condition).
Power contactor inoperative. Control the torch trigger.
The wire rubs down
after the rollers.
Covering wire guide crushed. Check the covering and torch body.
Locking of the wire in the torch Clean or replace.
No capillary tube. Check the presence of capillary tube.
Wire speed too fast Reduce the wire speed
The welding cord is
porous
The gas ow rate is not sufcient.
Adjusting ow range 15 to 20 L / min. Clean the working
metal.
Gas bottle empty. Replace it.
Gas quality non-satisfying. Replace it.
Air ow or wind inuence. Avert air blast, protect welding area.
Gas nozzle too full. Clean or replace the gas nozzle.
Bad wire quality. Use adapted WIRE for MIG-MAG welding.
Surface to weld in bad condtion. (rust, etc,
...)
Clean the working parts before welding.
Very important ashing
particules.
Arc voltage too low or too high. See welding settings.
Bad earth connection.
Check and place the earth cable to have a better
connection.
Protecting gas insufcient. Adjust the gas ow.
No gas at the torch
output.
Bad gas connection.
See if the gas coupling beside the engine is well
connected. Check the owmeter and the solenoid
valves.
In general
The machine does not
deliver any current and
the thermal overload
indicator lamp lights
up.
The welder thermal protection has turned
on.
Wait for the end of the cooling time, around 2 minutes.
The indicator lamp turns off.
The display is on but
the device does not
deliver any current.
The cable of the earth clamp or electrode
holder is not connected to the welder.
Check the connections.
If, when the unit is on
and you put your hand
on the welding unit’s
body, you feel tingling
sensation.
The welding unit is not correctly
connected to the earth.
Check the plug and the earth of your electrical
network.
The display is on but
the device does not
deliver any current.
The cable of the earth clamp or electrode
holder is not connected to the welder.
Check the connections.
When starting up, the
display indicates
.
The input voltage is outside of the range
(230V + 15% for single phase or 400V +
15% for 3-phase).
Have the electrical installation checked.
TIG
Instable arc
Default coming from the tungsten electrode
Use a tungsten electrode with the adequate size
Use a well prepared tungsten electrode
Too important gas ow rate Reduce gas ow rate
The tungsten electrode
gets oxidised and tern
at the end of welding.
Welding zone Protect welding zone against air ows
Default coming from post-gas or the gas
has been stopped prematurely.
Check and tighten all gas connections. Wait until the
electrode cools down before stopping the gas.
The electrode melts Polarity error Check that the earth clamp is really connected to +
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gys MULTIPEARL 200-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info