564781
13
Zoom out
Zoom in
Vorherige Seite
1/33
Nächste Seite
13
Tip!!
Only when commissioning, place about 30 pellets in
the burner. This will speed up the ignition process.
General:
If the ignition phase could not be successfully run i.e. no
flame generation or the required temperature could not
be reached at the flue gas thermosensor, then a safety
shutdown is initiated and an error message generated
(“Ignition phase target temp. flue gas not reached
check burner date and time”).
Note: Any smoke generation caused by further
drying of the paint stops after a short while. Please
properly ventilate the room where the stove is
installed. However, the paint does not contain any
toxic vapours.
8. Cleaning and maintenance work
The functioning of your device depends to a large extent
on regular expert maintenance. Because of the ash
accumulation resulting from the combustion of wood
pellets, constantly recurring cleaning and maintenance
work needs to be carried out. This will permit operation
to be as trouble-free as possible.
The frequency of maintenance in turn depends to a large
extent on the pellet quality (ash content). Quality pellets
have a low ash content of about 0.2-0.3%. However, if
the ash content is higher (0.5% and over), the interval
from maintenance to maintenance is reduced and the
accumulation of ash increases by 2 or 3 times. This
results in lower heat output and an increased fan
rotation speed. We therefore recommend
checking and/or cleaning the flue gas passes
after 1,000 kg of pellets at the latest. (See
Figure 8 a+d).
Attention!
Devices that are not maintained in accordance with
our specifications must not be operated. Failure to
observe this point will invalidate all guarantee
claims.
As soon as you detect ash and clinker deposits in the
cold combustion pot, it must be cleaned. (See Figures 5
+6). If this is not done, the clinker will continue to
accumulate. Then the device will no longer be able to
ignite properly. Pellets can pile up in the combustion pot.
In extreme cases, this can reach all the way back to the
pellet chute. Backfire in the pellet container and
smouldering in the pellet tank might possibly result.
This will destroy your device and is not covered in
your guarantee.
Attention!
Before starting any cleaning work, the stove must be
cool down and set to "Off"! Once the cleaning work
is completed, the correct operating status of the
device must be re-established: Put the combustion
pot in correctly, close the combustion chamber
door.
8.1. Cleaning the surface
Dirt on the upper surface of the stove may be cleaned
off with a damp cloth or if necessary with mild soapy
water. You are advised against using corrosive cleaning
agents and solvents since these might damage the
surfaces.
8.2. Cleaning the glass panel
To clean the viewing panel, you must first open the
stove door. Dirt on the glass panel can be removed with
a glass cleaner or with a damp sponge on which you
have sprinkled some of the wood ash present.
(Environmentally friendly).
Cleaning the glass panel may only be done with a
cooled down stove in the OFF operating mode.
8.3. Clean combustion chamber” function
instruction
Die The display on the operator console starts flashing.
(The backlighting switches on and off and the “Clean
combustion chamber” instruction appears).
The instruction to clean the combustion chamber refers
not just to the cleaning of the burner but also to the
cleaning of the entire combustion chamber with an ash
vacuum cleaner.
The process of the “Clean combustion chamber”
function looks like this:
The entire combustion chamber is to be cleaned with an
ash vacuum cleaner at intervals of no longer than 30
operating hours.
The process of the “Clean combustion chamber”
function looks like this:
The entire combustion chamber is to be cleaned with an
ash vacuum cleaner at intervals of no longer than 30
operating hours.
However, this instruction to clean the combustion
chamber (display flashing) does not trigger an error
message during Heating mode. But after the display has
started flashing, if the stove switches
back to “Standby” mode, the stove can no longer be
automatically ignited before the combustion chamber
has been cleaned.
To clean the combustion chamber, the stove has to be
switched to “Off” operating status.
If the combustion chamber is now cleaned, then the
“Clean combustion chamber” error message will
thereafter be cleared automatically. A precondition for
the automatic clearance of this error message is that the
combustion chamber door is open for longer than 60
seconds in “Off” operating status. This time is required
for cleaning the combustion chamber including the
burner thoroughly with an ash vacuum cleaner.
If the door is open longer than 60 seconds in “Off”
operating status, then the operating hours counter,
which is responsible for the “Clean combustion
chamber” instruction, is automatically reset to zero.
This reset of the operating hours counter occurs even if
the cleaning of the combustion chamber is performed
before the 30 operating hours have run provided that the
stove is in “Off” operating status and the door is open for
longer than 60 seconds during cleaning.
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Haas-Sohn PALLAZZA-II 534.08 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Haas-Sohn PALLAZZA-II 534.08

Haas-Sohn PALLAZZA-II 534.08 Bedienungsanleitung und Installationsanweisung - Deutsch - 34 seiten

Haas-Sohn PALLAZZA-II 534.08 Bedienungsanleitung - Französisch - 35 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info