Indoor Unit Installation
Fix to side bar and lintel a mounting bar, Which is separately sold, and
then fasten the plate to the fixed mounting bar.
Refer to the previous article, “ When the mounting plate is fi
position of wall hole.
Make a hole of 60 mm in diameter, slightly descending to outside the wall
Install piping hole cover and seal it off with putty after installation
1. Carry out, based on the neighboring pillars or lintels, a
to be fixed against the wall, then temporarily fasten the plate
with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread
with a weight from the central top of the plate, then fasten securely the
plate with the attachment steel nail.
3. Find the wall hole location A/C using a measuring tape
When the mounting plate is fixed side bar and lintel
Fitting of the Mounting Plate and Positioning of the wall Hole
Lid for right
piping
Lid for under piping pipe
Fix with adhesive tape
Lid for left piping
Indoor/outdoor electric cable and drain hose must be bound with
efrigerant piping by protecting tape.
[ Other direction piping ]
Cut away, with a nipper, the lid for piping according to the piping
direction and then bend the pipe according to theposition of wall
hole. When bending, be careful not to crash pipes.
Connect beforehand the indoor/outdoor electric cable, and then
pull out the connected to the heat insulation of connecting part
specially.
proper leveling
for the plate
rst fixed ,
for the
Making a Hole on the Wall and Fitting the Piping Hole Cover
Drawing of pipe
Installation of the Indoor Unit
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left
piping.
In case of left-rear piping, bend the pipes according to the piping
direction to the mark of hole for left-rear piping which is marked on
heat insulation materials.
1. Insert the drain hose into the dent of heat insulation materials of
indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor
unit,and pull it out on the front side, then connect them.
3. Coat the flaring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely,
and make sure fixing with adhesive tape
Hang surely the unit body onto the upper
notches of the mounting plate. Move the body
from side to side to verify its secure fixing.
In order to fix the body onto the mounting
plate,hold up the body aslant from the
underside and then put it down perpendicularly.
Remove terminal cover at right bottom corner of
indoor unit, then take off wiring cover by removing
its screws.
mounting plate
When you unload the indoor unit,please use your hand to arise
slightly and lift the unit aslant until it leaves the mounting plate.
agraffe mounting plate
the body to leave agraffe,then lift the bottom of the body outward
Heat insulation
material
Drain hose
Piping
Pipe supporting
plate
Indoor/outdoor electric cable
Indoor side Outdoor side
Ø60mm
Wall hole
Thickness of wall
(Section of wall hole) Piping hole pipe
G
When the mounting plate is first fixed
Fixing the indoor unit body
Unloading of indoor unit body
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
12
A=170mm C=130mm B=
Ø
60mm
D=47mm
A=222mm C=165mm B=
Ø
60mm
B=
Ø
60mm
B=
Ø
60mm
D=41.5mm
D=41.5mm
A=218mm C=151mm
B=
Ø
60mm
B=
Ø
60mm
D=38.5mm D=38.5mm
9K/12K/15K
18K
24K
D=47mm
(20/25/35/42)
(50)
(71)
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Haier Flexis serie wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Haier Flexis serie

Haier Flexis serie Bedienungsanleitung - Holländisch - 19 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info