WAR NING:
·If th e supply co rd is damaged, it must be replaced by the manufacturer,its service agent or
similarly qualified persons in order to avoid a ha zard.
·
·All the cables shall have go t the European au the nti cation certific ate. During installation, when the
·c onnecting cables break off, i t must be assured that the grouding wire is the last one to be broken off.
The explosion-proof breaker of the air conditioner should be all- pol e switch. Distance between its two
contacts should be not less than 3mm. Such means fordisconnection must be incorporated in the
·Ma ke s ure ins tall ation is done acco rding to local wiring re gulation by professional persons.
·
·A lea kage explosion-proof breaker must be installed.
Make sure ground connection is correct and re liable.
Read t he pr ecaut io n s i n thi s man u al
car ef ul ly befo r e op er ati ng t h e un it . Th is app lia nce is fi ll ed wi th R32.
Do not use means to accelerate the defrosting proces s or to clean, other than those
recommended by the manufacturer.
·
Keep th is manual where th e user ca n easily d it.
The appliance must be stored in a room witho ut continuo usly operating ignition sources (for
example: open flames, an operating gas appliance or an operating electric heater).
Do not pierce or burn.
·
·Be aware that refrigerants may not contain an od our.
·The a pp lianc e must be installed, operated and stored in a room with a floor area larger than
3m.
·
·Do not use a refrig er ant other than t he one indicat ed on th e outdoor unit(R32) when installing,
moving or repairing. Using other refrigerant s may cause trouble or damage to the unit, and
personal injury.
wiring.
2
1
This appliance can be used by c hildre n aged 8 ye ars and ab ove and pe rsons with reduced
physical, sensory or mental( mentao) capabilities or lack of exper ien ce and
knowledge if they have been giv en superivisio n or i nst ruction concering use of the
appliance in a safe way and unde rs tand the h azards involved. Chi ldren shall not play with
the appliance.
The appliance shall be installed in accordance with national wiring regulations
Loading and Unloading/Transporti ng Management/St orage Requirement s
1) The produc ts shall be caref ully handled during loading and unloading.
2) Rude and barbarous handling such a s kickin g, throwing, dr opping, bumping, pulling a nd r ol ling is not
allowed.
3) The work e rs engage d in loading and unloading m ust be subject to nece ssary tr a inings on the potential
hazards caus e d by barbarous handli ng.
4) Dr y powder e xtinguishers or other suitable fire extinguishing apparatus within the period of validity shall be
equipped at the loading and unloading site.
5) The untrained personnel cannot be engaged i n loading and unloading of f lammable refrigerants air
conditioner.
6) Befor e loading and unloading, anti-static measures shall be taken, a nd phones c annot be answ ered during
loading and unloading.
7) S moking and open fire are not allowed around the air c onditioner.
Transporting Managem ent Requirem ents
1) The maximum t ransporting volume of finishe d products shall be determined as per local regul a tions.
2) The vehicles used for transpor ting shall be operated as per loc al laws and regu lations.
3) Dedicated after-sales vehicles shall be used for maintenance, and exposed transporting of refrigerant
cylinders and the products to be maintained is not allo wed.
4) The rain c over or similar shielding material of transporting vehicles s hall be provided with certain f lame
retardancy .
5) Le akage warning device of flammable refrigerant s hall be installed inside the close d-type compartment.
6) Anti -stati c device shall be e quipped inside the compa rtment of transporting vehicles.
7) Dr y powder e xtinguishers or other suitable fire extinguishing apparatus within the period of validity shall be
equipped ins ide the driver's cab.
8) Orange-white or red-white ref lective stripes shall be pasted on the sides and tail of the transpor ting vehicles,
to remind the vehi cles behind of ke eping distance.
9) The tra nsporting vehicles shall run at a constant speed, and heavy acceleration/deceleration shall be avoided.
10) C ombus tibles or the static articles cannot be transported simultaneously.
11) High- temperature area shall be a voided during transporting, and ne cessar y radiati ng measures shall be taken
in case the temperatur e inside the compartme nt is too high.
Storage Requ irements
1) The storage package of equipment used shall be such that no leakage of refrigerant will be caused due to
mechanical dam age of the equipment i nside.
2) The maximum quantity of the equipm ent al l owed to be s tored together s hall be determined as per local
regulations .
Installation Instructions
WARNING!
The area of the r oom in which R32 refrigerant air conditioner is installed cannot be less than the minimum
area spec ified in the table below, to avoid potential s afety probl em s due to out-of-limit of r efrigerant
concentration inside the room caused by lea kage of refrigerant from refrigeration system of the indoo r unit.
Once the horn m outh of connecting lines is fastened, it m ay not be used aga in (the air ti ghtness m ay be
affected).
A whole connector wire shall be used f or indoor/outdoor unit as required in the operation specification of
installation pr ocess and operati on instructions.
Minimum Room Area
Type L FL
kg/m3
Total Mass Charged/kg
Minim um Room Area/m2
R32 0.306
1.224 1.836 2.448 3.672 4.896 6.12 7.956
3 6 13 23 36 60
2
The maxim um refrigerant charge a mount (M)
Unit model M kg Un i t m odel M kg Unit model M kg Unit mo del M kg
1U20YE EFRA 0 .62 1U25S2S M1FA 0.85 1U35MEEF RA 0.82 1U50JEFF RA- TCS 1.3 5
1U2 5BEE FRA 0 .74 1U25Y EM FRA 0. 67 1U35S2PJ1FA 1. 15 1U50M EE/M FRA 1.3 0
1U2 5BEF FRA 0.90 1U35BEEF R A 0 .82 1U35S2SM1 FA 1.14 1U50S2SJ2FA 1.35
1U2 5BEF FRA-T CS 0.90 1U35BEEF RA- TCS 0.82 1U3 5Y EMFR A 0.70 1U68R EE/ F/ MF R A 1 .60
1U2 5S2PJ1F A 1.15 1U 35B EFFRA 0.92 1U50JEF FRA 1.35 1U71S2SR1FA 1.60
1U4 2S2SM 1FA 1.14 1U50 S2PR1FA 1.60 1U25JEJ FRA 1U35JE JFRA
1U50R EJFRA 1 .60
0.94 0.94
1U71REA FRA 1.60
1. Proc edures: operation shall be made as per controlled procedures to minimize t he probabilit y of risks.
2. Area: area shall be divided and i solated approp riately, and operation in an enclosed space shall be avoided.
Before the refrigeration syste m is s tarted or bef ore hot working, ventilati on or opening of the ar ea sha ll be
guaranteed.
3. Site inspection: the refrigerant shall be checked.
4. Fire control: the f ire extingui sher shall be placed nearby, and f ire source or high temperature is not allowed;
the sign of “No smoking” shall be arranged.
1. Indoor unit: nitrogen is sealed during the delivery of indoor units (inside the evaporator), and the red sign at
the top of the green plastic seal ca p on the evaporator air pipes of the indoor unit shall be checked f irst after
unpacking. In case the s ign is r aised, the nitrogen sealed still exists. Afterwards, the black plastic seal cap at the
joint of evaporator liquid pi pes of the indoor unit shall be pressed, to check whether nitrogen still exists. In case
no nitroge n is sprayed out, the indoor unit is subject to leakage, and install ation is not allowed.
2. Outdoor unit: t he leak detection equipm ent shall be extended into the packing box of the outdoor uni t, t o
check whether the refrigerant is leaking. If the refrigerant leakage is identified, installation is not allowed, a nd the
outdoor un it shall be delivered to the maintenance department.
1. The room area chec ked cannot be less than the area specified on the warn ing sign of the indoor unit.
2. Inspection on the s urr ounding environment of place of installation: the outdoor unit of flammable
refrigerant s air conditioner cannot be insta lled inside an enclosed room reserved.
3. Power supply, switches or othe r hi gh-temperatur e articles s uch as t he f ire source and oil heater shall be
avoided below the indoor unit.
4. The power supply shall be provide d with earthing wire and be reliably ea rthed.
5. While punching the wall with an electric drill, whether embedded water/elec t ricity/ gas pipelines are
designed at the hole preset by the user shall be verified in advance. It is recommende d that the thr ough-wall hol es
reserved shall be used as much as possible.
1. Favorable ve ntilation shall be maintained at the place of installation (doors and windows are opened).
2. Open fire or high-temperature heat source (includi ng welding, smoking and oven) higher than 548 is not
allowed withi n the scope of flamm able refri ge rant.
3. Anti- static measures shall be ta ke n , such as the wearing of cotto n clothes and cotton gloves.
4. T he place of installation shall be convenient for installation or maintenance , and cannot be adjacent to heat
source and flam mable and combustible environment.
5. In case of refrigerant leakage of the indoor unit during installation, the valve of t he outdoor unit shall be
closed immediately, and windows shall be opened, and all the personnel shall be evacuated. After the leakage of
refrigerant is handled, the indoor environment shall be subject to concentration detection. Further handling is not
allowed until the safety level is reache d.
6. In case t he pr oduc t is da maged, it must be delivered to the maintenanc e point . We lding of ref rigerant
pipelines at the user’s site is not allow e d.
7. The installation position of air conditioner shall be convenient for installation or maintenance. B arriers shall
be avoided a round t he air inlet/outlet of the indoor/outdoor unit, and the electrical appliance , power s witches,
sockets, valuables and high-temperature products within the scope of both sidelines of the indoor unit shall be
avoided.
3
No fire source around the
place of installation
Rea d opera tor’ man ual Read tec hnical m anual Operato r’ manu al ope rating instructio ns
Cotton clothe s Anti - static gl ove s BEWA RE
ELECTROSTATICS Goggles