TECHNICAL DATA Solution 5kW
Inset S4
Solution 7kW
Inset S4
Nominal Heat Output—Wood (Kw) 5.0 7.1
Efficiency Nett At Nominal Heat
Output (%) 79.9 75.4
Mean Flue Gas Temperature (°C) 274 326
Mean CO Emission @ 13% O2 (%) 0.08 0.11
Flue Mass Gas Flow (g/s) 4.1 6.23
Typical Fuel Load To Achieve
Nominal Rated Output Per Hour
(Kwh/Kg) (Seasoned Hardwood)
1.44 1.62
Mean CH Emission @ 13% O2 (%) 79 92
Mean NOx Emission @ 13% O2 (%) 97 95
DIN Plus Particulates @ 13% O2 (%) 14 27
Ideal Log Length & Diameter (mm) 200 / 100 300 / 100
Nominal Heat Output—Solid fuel (Kw) 5.0 7.1
Efficiency Nett At Nominal Heat
Output (%) 76.0 75.8
Mean Flue Gas Temperature (°C) 323 332
Mean CO Emission @ 13 % O2 (%) 0.07 0.08
Flue Mass Gas Flow (g/s) 4.1 6.4
Typical Fuel Load To Achieve
Nominal Rated Output Per Hour
(Kwh/Kg) (MSF Maxibrite)
0.76 1.08
Mean CH Emission @ 13% O2 (%) 30 43
Mean NOx Emission @ 13% O2 (%) 138 159
DIN Plus Particulates @ 13% O2 (%) 12 27