6.4 Warning - Fume / Smoke emissions
Properly installed, with a suitable flue or chimney, operated and maintained correctly, this
appliance will not emit fumes into the dwelling. Occasional fumes when de-ashing and
refuelling may occur. However, persistent fume emission is potentially dangerous and must
be investigated by an approved / registered installer.
WARNING!
STOP USING THE APPLIANCE IF YOU SMELL FUMES OR SEE SMOKE ESCAPING.
If fume emission does persist, the following immediate actions should be taken:
• Open doors and windows to ventilate room.
• Let the fire die or extinguish and safely dispose of fuel from the appliance.
• Check for flue or chimney blockage, and clean if required.
Seek expert advice from your approved installer.
Do not attempt to re-light the fire until the cause of the fume emission has been identified
and corrected.
6.5 Refuelling on to a low fire bed
If there is insufficient burning material in the fire bed to light a new fuel charge, excessive
smoke emission can occur. Refuelling must be carried out onto a sufficient quantity of
glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there
are too few embers in the fire bed, add suitable kindling for ignition to prevent excessive
smoke.
Important notes on usage, to meet the requirements of Smoke Control exemption -
• Always recharge onto hot embers.
• After re-charging, fully open both the primary and secondary air controls for the
following times, in order to establish good combustion -
Hamlet Solution 4kW S4—3 minutes with the fire door ajar
Hamlet Solution 5kW Compact S4 — 3 minutes with the fire door ajar
Hamlet Solution 5kW S4—2 to 3 minutes
Hamlet Solution 5KW Widescreen S4—3 minutes with door ajar
Hamlet Solution 7kW S4—3 minutes with door ajar
• Do not leave the appliance unattended until flames are well established.
• Periodic burning out of the fuel bed at high output to combust any remaining
charcoal.