Frequently Asked Questions
Malfunction of the buttons, the keys, etc.
Turn off the POWER switch once, then turn it on again. If this procedure is not successful, turn off the
POWER switch. While pressing the [RECORD] button, turn the POWER switch on again. (Note that in this
case, all parameters return to their factory-preset status.)
No sound is produced when the keys are pressed.
The MASTER VOLUME is at the minimum setting.D
Adjust the volume with the MASTER VOLUME control. (P. 22 #25)
No Preset key is selected. D
Select a Preset key.
A plug is inserted to the HEADPHONE jack. D
While a plug is inserted here, the Leslie speaker is disabled.
The Foot Switch does not work.
The Foot Switch settings are not correct.D
Reset the Foot Switch correctly in the CONTROL mode. (P. 91 #4)
The sound does not come out immediately after switched on.
A Vacuum Tube circuit is mounted in this organ. It takes approximately 10 to 20 seconds after switched on
before you will hear the sound.
The sound is not distorted if the OVERDRIVE knob is turned.
When the Overdrive Expression is at “EX-OD”, it does not distort if the Expression pedal is low. In such a
case, increase the Expression pedal, or set the Overdrive Expression at “OD-EX” if you want to distort
regardless of the Expression value. (P. 80 #1)
Leslie speaker sound is distorted.
If the sound is distorted regardless of the position of the volume of the Leslie speaker when you are using a
Leslie adapter (such as the 11 pin/6 pin converter), the power of this organ seems to be so large that the sound
is distorted inside the Leslie adapter. In such a case, return the [MASTER VOLUME] knob to 10 o’clock
position.
The rotor of the external Leslie speaker does not stop, if the Leslie mode is switched
to [STOP].
Some Leslie Speaker models do not [STOP]. [STOP] is possible on 2101/2102, 122XB, 971 and 3300 (cur-
rent models).
Audio is interrupted when a Combination Preset is selected.
Between the Combination Presets with different Tonewheel Settings, the sound will be cut off while the
Tonewheel Settings are switched.
The sound is once cut between the presets with different key mode (MONO/POLY) on the Pedal part, for
switching the sound algorithm.
There is excessive MIDI latency compared to the organ (Drawbar) sound.
The position of the key contact for MIDI send is deeper than that of the multi-contacts for Drawbars.
There are too many zones to send. D
Turn [OFF] the switches of unnecessary external zones.
No sounds of Pedal part from the headphones.
PEDAL OUTPUT set at “PEDOUT”. D
Set the PEDAL OUTPUT at “BOTH” when using the headphones (P. 96 #1).
Manual contact does not work well.
The multi-contacts used for the manuals on this organ is designed to be used for a long time. Refer for the
contact refreshing procedures to the “Instruction for keyboard contact cleaning function”.
And, if all the contact points have been worn out and the problem is not solved any longer by refreshing the
contacts, please consult your local dealer or store for further maintenance.
TROUBLESHOOTING
115

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hammond B-3 mk2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info