Harman® • Absolute63 Owner ’s Manual_R27 • 2016 -___ • 08/2323-90-999000C
BARCODE LABEL
HF
Serial No.
No de série:
Model: ABSOLUTE63
Room Heater Pellet Fuel-Burning Type
SUITABLE FOR MOBILE-HOME INST ALLATION
This pellet burning appliance has been tested and listed for use In
Manufactured Homes In accordance with OAR 814-23-900 through 814-23-909
352 Mountain House Road, Halifax, P A 17032 (É.-U.) US ENVIRONMENTAL PROTECTION AGENCY
Certifi ed to comply with 2020 particulate emission standards.
Certifi é conforme aux normes 2020 d’émission de particules.
Date of Manufacture / Date de fabrication
2023 2024 2025 JAN FEB MAR APR MA Y JUN JUL AUG SEP OCT NOV DEC
Manufactured by/Fabriqué par: Hearth and Home Technologies
Test to/testé à: ASTM E2779, ASTM E2515,
ASTM E1509, ULC-S627, EPA Method 28R
Test date: March 2016
Room Heater, Pellet Fuel-Burning T ype, Also
For Use In Mobile Homes. (UM) 84-HUD
“PREVENT HOUSE FIRES” Install and
use only in accordance with manufactures
installation and operation instructions.
Contact local building or fi re offi cials about
restrictions and installation inspection in your
area.
WARNING: FOR MANUFACTURED HOMES:
Do not install appliance in a sleeping room. An
outside combustion air inlet must be provided.
The structural integrity of the manufactured
home oor , ceiling and walls must be
maintained.
Refer to manufacturer’s instructions and local
codes for precautions required for passing
chimney through a combustible wall or ceiling.
Inspect and clean exhaust venting system
frequently in accordance with manufacturer’s
instructions.
Use a 3” or 4” diameter type “L” or “PL” venting
system.
Do not connect this unit to a chimney ue
servicing another appliance.
Do not obstruct the space beneath the heater.
FOR USE WITH PELLETIZED WOOD FUEL
ONL Y.
EP A Certifi ed Emissions: 1.4 g/hr
Input Rating Max: 7.6 lb. fuel/hr
Electrical Rating: 240 VAC, 50 Hz, Start 1.75
AMPS, Run 1.25 AMPS
U.S. Electrical Rating: 115 V AC, 60 Hz, Start
3.5 AMPS, Run 2.5 AMPS
Fuel Type: W ood Pellet Only
THIS AREA MUST
BE BLACK
6"
2"
6.25"
6.25"
AC
B
MINIMUM CLEARANCES TO
COMBUSTIBLES
Back Wall to Appliance 2”
Side Wall to Appliance 6"
Corner Installation
Walls to Appliance 6.25”
Use a non-combustible oor protector
extending under and to the sides, front
and back of the unit as shown in oor
protection diagram. Measure front
distance from the surface of the glass
door.
Recommended: Non-combustible
fl oor protection extended beneath
the fl ue pipe when installed with
horizontal venting.
Floor Protection*
USA CANADA
Sides (A) 6” 152 mm
Back (B) 1” 25 mm
Front (C) 6” 152 mm
Alcove Installation
Min. Alcove Height 48” (1219mm)
Max. Alcove Depth 36” (914mm)
Report #/Rapport # 0135PS036S & 0135PS036E
Modèle: ABSOLUTE63
Appareil de chauffage à granulés de bois
CONÇU POUR MAISONS MOBI LES
DANGER:
Risque d’électrocution. Coupez
l’alimentation électrique avant l’entretien.
Remplacer le verre avec 5 mm miroir verre
céramique de la même qualité disponible auprès de
votre revendeur.
En tenant la porte d’entrée et le couvercle de la trémie
hermétiquement fermé pendant le fonctionnement de
l’appareil
DIST ANCES DE SECURITE PAR RAPPORT AUX
MA TERIAUX COMBUSTIBLES
Paroi arrière à l’appareil 51 mm
paroi latérale de l’appareil 152 mm
Installation en angle
Entre murs et apparell 159 mm
Installation en alcôve
Hauter minimale de l’alcôve 1219 mm
Profondeur maximale de l’alcôve 914 mm
PROTECTION DU SOL*
Côtés (A) 152 mm
Arrière (B) 25 mm
Avant (C) 152 mm
Utiliser une protection de sol non combustible sous
l’appereil qui s’étend sur les côtes, l’avant et l’arrière
du poêle (voir schéma). Pour la distance à l’avant,
mesurer à partir de la surface de la porte en verre.
ll est recommendé que la protection s’étende jusque
sous le conduit en cas d’installation d’un conduit
horizontal ou sous le té en cas conduit vertical.
Do not remove this label/Ne pas enlever cette
étiquette.Made in the USA/Fabriqué aux É.-U.
3-90-063_R8
Route power cord away from unit.
OPERATE ONL Y WITH DOORS CLOSED
DANGER: Risk of electrical shock. Disconnect power supply before servicing.
Replace glass only with 5mm ceramic available from your dealer.
For further instruction refer to owner’s manual.
Keep viewing and ash removal doors tightly closed during operation.
T est pour / tested à la norme ASTM E2779, A STM E2515,
ASTM E1509, ULC-S627, EP A Method 28R
Date du test: juillet 2015
Appareil de chauf fage à granulés de type com bustion de
carburant (UM ) 84 - HUD
"PRÉVENIR LES FEUX DE MAISON" Installer et utiliser
uniquement en conformité avec in stallation et d'utilisation
les instructions du fabricant.
Contactez les respons ables de feu ou de construction
locales sur les rest rictions et l'inspection dans votre région.
A VERTISSE MENT : POUR maisons préfabriquées: Ne
pas inst aller l'appareil dans une salle de repos. Une entrée
d' air de combustion à l'extérieur doit être fournie. L' intégrité
de la structure du plancher de la maison, le plafond et les
murs fabriqué doit être maintenue.
Reportez-vous aux instructions du fabricant et les codes
locaux pour connaître les précautions nécessaires pour
faire passer la cheminée à travers un mur ou un plafond
combustible. Inspectez et nettoyez système d'évacuation
des gaz d'échappement souvent en conformité avec les
instructions du fabricant.
Utilisez un type de diamètre "L" 3 "ou 4" ou "PL" du système
de ventilation.
Ne pas connecter cet appareil à un conduit de cheminée
servant un autre appareil.
Ne pas obstruer l’espace sous le chauffe-eau.
POUR UTILISATION AVEC GRANULE DE BOIS.
Entrée Puissance Max: £ 7,3 combustible / h
Puissance électrique: 240 V , 50 Hz, Lancer 1.75 AMPS,
Exécuter 1.25 AMPS
États-Unis électrique Note: 1 15 V AC, 60 Hz, Lancer 3.5
AMPS, Run 2.5 AMPS
Type de carburant: granulés de bois, 5 mm de diamètre.
Route cordon électrique de l'appareil.
FAIRE FUNCTIONNER UNIQUEMENT LORSQUE LES
PORTES SONT FERMÉES
LABEL TICKET
ECO: 98772 LABEL SIZE: 13” X 5.75”
P ART # / REV : 3-90-063_R8 ADHESIVE:
ORIGINA T OR: Spidlet MA TERIAL: 24 Gauge Aluminum
DA TE: 03/22/23 INK: Black Background
(3)SlottedHoles=.156x.25
(1)Hole=Ø.156
(2) Holes = Ø.375
(4)Corners=R.062
This unit will need the addendum label that refers to the
“W ood heater needs periodic inspection” Information
352 Mountain House Road
Halifax,P A 17032
Congratulations, The Harman® Absolute63 pellet stove you
have selected is designed to provide the utmost in safety ,
reliability ,andeciency .
Asthe owner of a new pellet stove,you’ll want to read and
carefully follow all of the instructions contained in this owner’s
manual. Pay special attention to all cautions and warnings.
This owner ’ s manual should be retained for future reference.
We suggest that you keep it with your other important
documents and product manuals.
Y our new Harman® Absolute63 Freestanding Pellet Stove will
give you years of durable use and trouble-free enjoyment.
Welcome to the Harman® family!
Note: Cast iron is an artisan crafted material, which is
made the same way today as nearly 2000 years ago. Due
to the intrinsic primitive nature of the casting process,
part to part variation is normal and adds to the character
of a hand built cast iron appliance
Read this manual before operating this appliance.
Please retain this Owner ’ s Manual for future reference.
Read the Installation Manual before making any installation or nishing changes.
Listing Label Information/Location The model information regarding your specic stove can be found on the
rating plate usually located in the control area of the stove.
Model Name SerialNumber
EXAMPLE