625438
13
Zoom out
Zoom in
Vorherige Seite
1/17
Nächste Seite
EN DE
13
3.3. Electrical Connections
The heater may only be connected to the electrical
network in accordance with the current regulations
by an authorised, professional electrician.
• The heater is semi-stationarily connected to the
junction box (figure 10: 3) on the sauna wall.
The junction box must be splash-proof, and
its maximum height from the floor must not
exceed 500 mm.
• The connecting cable (figure 10: 4) must be of
rubber cable type H07RN-F or its equivalent.
NOTE! Due to thermal embrittlement, the use
of PVC-insulated wire as the connecting cable
of the heater is forbidden.
• If the connecting and installation cables are
higher than 1 000 mm from the floor in the
sauna or inside the sauna room walls, they
must be able to endure a minimum temperature
of 170 °C when loaded (for example, SSJ).
Electrical equipment installed higher than
1 000 mm from the sauna floor must be
approved for use in a temperature of 125 °C
(marking T125).
• In addition to supply connectors, the M heaters
are equipped with a connector (P), which makes
the control of the electric heating possible
(figure 12). Voltage control is transmitted from
the heater when it is switched on. The control
cable for electrical heating is brought directly
into the junction box of the heater, and from
there to the terminal block of the heater along
a rubber cable with the same cross-section
area as that of the connecting cable.
3.3. Elektroanschlüsse
Der Anschluss des Saunaofens an das Stromnetz darf
nur von einem zugelassenen Elektromonteur unter Be-
achtung der gültigen Vorschriften ausgeführt werden.
• Der Saunaofen wird halbfest an die Klemmdose
(Abb. 10: 3) an der Saunawand befestigt. Die
Klemmdose muß spritzwasserfest sein und darf
höchstens 500 mm über dem Fußboden ange-
bracht werden.
• Als Anschlusskabel (Abb. 10: 4) wird ein Gum-
mikabel vom Typ H07RN-F oder ein entspre-
chendes Kabel verwendet. ACHTUNG! PVC-
isolierte Kabel dürfen wegen ihrer schlechten
Hitzebeständigkeit nicht als Anschlusskabel des
Saunaofens verwendet werden.
• Falls der Anschluss oder die Montagekabel höher
als in 1 000 mm Höhe über dem Boden in die
Sauna oder die Saunawände münden, müssen sie
belastet mindestens eine Temperatur von 170 °C
aushalten (z.B. SSJ). Elektrogeräte, die höher als
1 000 mm vom Saunaboden angebracht werden,
müssen für den Gebrauch bei 125 °C Umge-
bungstemperatur zugelassen sein (Vermerk T125).
• Die M-Saunaöfen sind zusätzlich zum Netzan-
schluss mit einer Klemme (P) ausgestattet, wel-
che die Möglichkeit zur Steuerung der Elektro-
heizung bietet (Abb. 12). Der Ofen übernimmt
mit dem Einschalten die Spannungsregelung.
Das Steuerungskabel für die Elektroheizung
wird direkt zur Klemmdose des Saunaofens
gelegt und von dort aus durch ein Gummikabel
der gleichen Stärke weiter zur Reihenklemme
des Saunaofens geleitet.
3.3.1. Electric Heater Insulation Resistance
When performing the final inspection of the electri-
cal installations, a “leakage” may be detected when
measuring the heater’s insulation resistance. The
reason for this is that the insulating material of the
heating elements has absorbed moisture from the
air (storage, transport). After operating the heater
for a few times, the moisture will be removed from
the heating elements.
Do not connect the power feed for the heater
through the RCD (residual current device)!
3.4. Installation of the Control Unit and
Sensors (M-E)
The control unit includes detailed instructions for
fastening the unit on the wall. Install the temperature
sensor on the wall of the sauna room above the
3.3.1. Isolationswiderstand des Elektrosaunaofens
Bei der Endkontrolle der Elektroinstallationen kann
bei der Messung des Isolationswiderstandes ein
“Leck” auftreten, was darauf zurückzuführen ist,
daß Feuchtigkeit aus der Luft in das Isolationsmateri-
al der Heizwiderstände eingetreten ist (bei Lagerung
und Transport). Die Feuchtigkeit entweicht aus den
Widerständen nach zwei Erwärmungen.
Schalten Sie den Netzstrom des Elektrosaunaofens
nicht über den Fehlerstromschutzschalter ein!
3.4. Anschluß des Steuergerätes und der
Fühler (M-E)
In Verbindung mit dem Steuergerät werden genaue-
re Anweisungen zu dessen Befestigung an der Wand
gegeben. Der Temperaturfühler wird an der Sauna-
max. 500
1
2
4
3
1. Connection box
2. Control Unit
3. Junction box
4. Connecting cable
1. Anschlußgehäuse
2. Schaltmechanismus
3. Klemmdose
4. Anschlußkabel
Figure 10. Connections of the heater
Abbildung 10. Anschluß des Saunaofens
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Harvia M60E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info