6. SERVICING
During the rst 10-15 days, your system will require more attention:
- Check that the pH remains at the ideal level (7.2 to 7.4).
- If the pH is exceptionally unstable and uses a lot of acid, check the alkalinity (see table).
If the balance is highly unstable, contact your pool installer/builder.
REMEMBER that the system needs a certain amount of time to adapt to your pool and will require additional chemicals
during the rst 3-5 days.
The pool must be regularly maintained and the skimmer baskets emptied whenever necessary.
Also check that your lter is not clogged.
ADD WATER: It is preferable to add water via the skimmers so that it passes through the cell before entering the pool.
Remember to check the salt percentage after adding water.
DOSING PUMPS: Regularly check the acid level to ensure that the pump does not run dry. The dosing pump must be checked
and serviced at regular intervals. The Santoprene tube of the peristaltic pump has a lifetime of 2 years. We recommend that
you change it once a year.
Servicing the probe
The probe must be clean and free from oil, chemical deposits and contamination to function properly. As it is in continuous
contact with the water in the pool, the probe may need to be cleaned weekly or monthly, depending on the number of bathers
and other specic pool characteristics. A slow response, more frequent pH calibration and inconsistent readings indicate that
the probe needs to be cleaned.
To clean the probe, turn off the power to the AquaRite® Pro Touch.
Unplug the probe connector from the control box, unscrew the probe and carefully remove it from the chamber. Clean the
probe bulb with a soft toothbrush and regular toothpaste.
A household washing-up liquid detergent may also be used to remove any oil.
Rinse with fresh water, replace the Teon tape on the threads, and reinstall the probe.
If the probe continues to give inconsistent readings or requires excessive calibration after it has been cleaned, it should be
replaced.The lifetime of the probes is 1 year. We recommend that you calibrate them every month during the season the
pool is in use.
Servicing and cleaning the AquaRite® Pro Touch cell
Turn off the main power supply to the AquaRite® Pro Touch before removing the cell. Once it has been removed, examine the
inside of the cell for any traces of scale (whitish brittle or aky deposits) and debris stuck to the plates. If no deposits are visible,
reinstall the cell. If deposits are visible, try to remove them with a garden hose. If this method is unsuccessful, use a plastic or
wooden tool to remove deposits stuck to plates (do not use a metal tool as this will damage their coating). A build-up of deposits
on the cell indicates an exceptionally high concentration of calcium in the pool water. If you cannot nd a solution to this situation,
you will have to clean the cell at regular intervals. The best way to avoid this problem is to maintain the chemical composition of
the water at the recommended concentrations.
Acid washing: This should only be done in severe cases where ushing will not remove most of the deposits. To acid wash, turn
off the main power supply to the AquaRite® Pro Touch. Remove the cell from the piping. In a clean plastic container, make up
a solution of water and acetic or phosphoric acid (such as that used to remove scale from a coffee machine). ALWAYS ADD
ACID TO WATER – NEVER ADD WATER TO ACID. Be sure to wear rubber gloves and protective goggles for this operation.
The level of the solution in the container should just reach the top of the cell, so that the wire harness compartment IS NOT
under water. It may be helpful to coil up the wire before submerging the cell. Allow the cell to soak for a few minutes, then rinse
it with a garden hose. If the deposits are still visible, soak and rinse again. Put the cell back and examine it from time to time.
The lifetime of the cell is 3 years under ideal conditions. See the chapter on chemical water balance.
Wintering
The AquaRite® Pro Touch cell, the ow switch, probe and pool piping run the risk of being damaged if the water freezes. In
regions that experience long periods of cold weather, be sure to drain all the water from the pump and lter and from the
supply and return pipes before winter. Do not remove the control box.
Probe storage
The end of the probe must always be in contact with water or a solution of KCl. If it is removed from the measuring chamber,
it should be stored in the plastic cap provided (lled with water). If the storage cap has been mislaid, the probe should be
stored separately in a small glass or plastic container with its end immersed in water.
The probe must always be in a frost-free environment.
33

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hayward AquaRite Pro Touch Salt Chlorinator wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info