801904
12
Zoom out
Zoom in
Vorherige Seite
1/68
Nächste Seite
12
3.1 HYDROLYSIS 3.2 UV
1.1 Hydrolysis:
Programming of hydrolysis
functions.
1.2 Level: Desired disinfec-
tion level (%).
2.1 Ultraviolet: Programming
of UV system.
2.2 ON status: The UV system
will switch on automatically
when the filtration is on.
2.2 OFF status: The UV system will
never switch on automatically. On
this display, the partial and total
working hours of the lamps can be
verified.
1.2 Cover: Closed cover
detection.
Reduction of chlorine produc-
tion to percentage defined for a
pool with closed cover.
1.2 Boost: Continuous filtration for 24h
at max intensity. Auto return to program-
med filtration mode.
1.3 During the boost period the Redox
control can be deactivated.
Please refer to the section on operation
of the UV lamp for more information
Filtration must be activated in the menu before disinfection can be activated
4. MEASURES / Setpoints
4.1 4.2 4.3 4.1 Measures: Adjustment of setpoints and measuring probes.
4.2 Setpoints for each measurement.
4.3 Setpoints settings: Ideal setpoints for each of the parameters.
The default values are:
pH: 7.3-7.5; redoX: 600-800; Free Chlorine: 0.5-2 ppm;
Conductivity: 1500-2500 ppm for the AQR UV LS.
4.1 MEASURES / pH Calibration
4.5 4.64.4
Metering and control of
the pH of the water
Optional pH control 4.4 Calibration of pH probe:
Recommended every month during
usage season.
4.5 Calibration with buffers (buffer
solutions pH7 / pH10 / neutral):
Follow the instructions in 7 steps
that appear in the display (screen 4.6
corresponds to step 1).
4.7 4.8 4.7 Manual calibration: Allows to adjust the
probes at 1 point (without buffers) – only
recommended to adjust small deviation in
the readings.
4.8 Without removing the probe from the
water, use the plus/minus keys to adjust the
reading so it matches with your reference
value (photometer or other measurement).
pH
The redoX value advises us of the oxidation/reduction potential and is used to determine the level of water sterilization. The parameters or setpoints are the minimum/
maximum accepted redoX levels before the titanium cell is connected/disconnected. Adjusting the ideal redoX level (setpoint) is the last step in the system start up
sequence. To find the optimum redoX levels for your pool follow these steps:
1. Connect the pool filtration system (the salt in the pool must be adequately dissolved).
2. Add chlorine to the pool till a level of 1-1,5 ppm is achieved (approx. 1-1,5 gr/m3 of water). pH levels should be between 7,2 - 7,5.
3. After 30 min. test the free chlorine levels in the pool (manual test kit DPD1) if the free chlorine level is between 0,8 - 1,0 ppm.
Look at the redoX screen and memorize this level as the setpoint to CONNECT/DISCONNECT the electrolysis/hydrolysis cell.
4. The next day check free chlorine levels (manual test kit DPD1) and redoX. Raise/lower setpoint if necessary.
5. Remember to check the redoX set-point every 2-3 month and/or if the water parameters change (pH/temperature/conductivity).
4.2 MEASURES / redoX Calibration
Optional redoX control
Metering and control of the redoX
as check value of the free chlorine.
4.9 Calibration of the redoX probe:
Recommended every 2 months during
usage season.
4.10 Calibration with buffer (buffer
solution 465 mV): Follow the instructions
in 4 steps that appear in the display
(screen 4.11 corresponds to step 1).
4.12 4.13 4.12 Manual calibration: Allows to adjust
the probes at 1 point (without buffers) – only
recommended to adjust small deviation in
the readings.
4.13 Without removing the probe from the
water, use the plus/minus keys to adjust the
reading so it matches with your reference
value (photometer or other measurement).
redoX
4.114.104.9
2.2
2.11.1 1.2 1.3
+
-
+
-
+
-
+
-
+
-
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hayward AquaRite UV LS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info