Troubleshooting guide
As most malfunctions are related to a poor water balance, we advise you to check it before handling the product (see
chemical water balance).
Alarm text Possible causes Recommendation Action
“Flow” ashing Insufcient ow or no ow
Check the operation of the ow switch; if the contact is
closed, "FLOW" remains steady, otherwise it ashes.
The fault automatically
disappears once the
problem is resolved
Check that the lter pump is working correctly
Check the operating periods on the programming clock
Ensure that all the valves are open
Ensure that the water ows freely in the pipes
OFA Alr (pH)
Setting time too low Increase the pH OFA alarm time (20 minutes to
240 minutes)
Press CAL Enter to
remove the fault
Or set the pH OFA alarm
to OFF.
Acid container empty Replace the acid container
Rigid injection pipe blocked or pinched Inspect the acid injection pipe, replace if necessary
Peristaltic pump problem
Check pump operation, press the (+) button to force it to
operate, replace the pump if faulty
Inspect the membrane, replace if necessary
Difculty reading the pH or unstable pH Check the water balance and recalibrate the pH probe
OFA STOP (pH) pH level not reached after 3 cycle times See recommendation for pH OFA Alarm Press CAL Enter to
remove the fault
OFA Alr (Rx)
Setting time too low Increase the Redox OFA alarm time (20 minutes to
240 minutes) Press CAL Enter to
remove the fault
Or set the Rx OFA alarm
to OFF.
Chlorine container empty Replace the liquid chlorine container
Rigid injection pipe blocked or pinched Inspect the chlorine injection pipe, replace if necessary
Peristaltic pump problem
Check pump operation, press the (-) button to force it to
operate, replace the pump if faulty
Inspect the membrane, replace if necessary
Difculty to read Redox Check the water balance and recalibrate the ORP probe
OFA STOP (Rx) Redox level not reached after 3 cycle
times See Rx OFA Alr recommendation Press CAL Enter to
remove the fault
Parameter error System error Restore the default settings N/A
Electronic problem, replace the device
Error 7 pH
pH probe calibration problem Repeat the calibration
The fault automatically
disappears once the
problem is resolved
pH probe faulty Check the pH probe connection with the BNC connector
on the housing, inspect the probe and the cable
pH buffer solution out of date Obtain a new solution
Error 4 pH
pH probe calibration problem Repeat the calibration
pH probe faulty Check the pH probe connection with the BNC connector
on the housing, inspect the probe and the cable
pH buffer solution out of date Obtain a new solution
Error 465 mV
Rx probe calibration problem Repeat the calibration
Rx probe faulty
Check the connection of the Rx probe with the BNC
connector on the housing, inspect the probe and the
cable
Rx buffer solution out of date Obtain a new solution
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hayward EZ-Chem wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info