USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 3 of 5 Power-Flo II Rev. B
GENERAL
Install the pump at the right distance from the base in to minimize the distance between the suction point and the pump so
as to avoid pointless and excessive load losses in the hydraulic circuit.
However, it is mandatory to allow a safety distance (3.5 m minimum) as required by the current installation standard (p 2).
ZONE 2 ZONE 2
ZONE 0
1,50 m
2,50 m
2,50 m
1,50 m 2,00 m 2,00 m 1,50 m
ZONE 1
1,50 m
OK OK
3,5 m
ZONE 0
Install the pump in a ventilated and dry place. The motor requires air to flow freely around it to provide for natural ventilation.
The pump has to be installed, so that the plug and the wall socket outlet is easily visible and accessible.
The pump has to be installed, so that the external disconnect switch which is incorporated in the fixed wiring is easily visible
and accessible. The switch has to be located close to the pump.
The pump must be permanently mounted to a concrete base using lag screws suitable for concrete where pilot holes have
been drilled. Locking washers must be supplied to prevent loosening of the mounting lag screws over time. If the pump is
to be mounted to a wooden deck then lag screws suitable for wood must be used - with lock washers to prevent loosening
over time.
The acoustic level of the Hayward pumps is lower than 70 dB (A).
Necessary arrangements :
Connect the pump to ground
Fit a 30 mA residual current (RCD) device to protect people from electric shock caused by a possible break in the
electrical insulation.
Provide protection against short-circuiting (the definition of the rating will depend on the value indicated on the motor
name plate).
Provide a circuit separation device with a 3 mm opening on all the poles.
The single phase motors fitted to our pumps are provided with thermal protection. This protection operates on an overload
or in the event of abnormal heating of the motor coil and is reset automatically when the winding temperature drops.
If so required by regulations and whatever the motor type, in addition to the devices mentioned above, it is also necessary
to install a thermomagnetic protective device calibrated in accordance with the indications on the motor name-plate.
The table on page 42 indicates the various characteristics of the motors fitted to our pumps.
ELECTRICAL CONNECTION
Make sure that the power supply voltage required by the motor corresponds to that of the distribution network and that the
power supply cables matches the power and current of the pump.
All the electric connections of the pump and the possible change of power supply cable must be done by a qualified
professional so as to avoid all possible danger.
When making these electrical connections, refer to the diagram given under the lid of the motor terminal box.
Be sure to check the electric connections are tight and sealed before powering up. Replace all covers before operation.
The pre-wiring (test leads) that might be included on some of the pumps must be removed for final connection of the pump to the
electric power supply. This pre-equipment (test leads) is only used for works testing during the manufacturing phases.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hayward Power Flo II Pump wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info