741194
10
Zoom out
Zoom in
Vorherige Seite
1/26
Nächste Seite
_ TECNOEKA Srl _________________________________________________________ use and instruction manual _
_ page 10 ________________________________________________________________________________________
Connection of power cable
Mod. KCP96 V - KCP96 VS – KCR 96 V - The terminal board is on the rear panel of the
appliance. Open the terminal board cover by obtaining leverage with a screwdriver on the two
side fins. Loosen the cable gripper screw and allow the cable to pass through it. Arrange the
conductors so that the earth conductor is the last to detach from its terminal if the cable goes
into a state of faulty traction.
Connect the phase conductor to the terminal marked with the letter "L", the neutral
conductor to the terminal marked with the letter "N" and the earth conductor to the terminal
marked with the symbol . Tighten the ring-nut of the cable gripper and close the terminal
board cover. The appliance must be connected to an equipotential system whose efficiency
must first be checked according to current legal regulations. This connection must be made
between different appliances by using the appropriate terminal marked with the symbol . The
equipotential conductor must have a minimum diameter of 10 mm
2
The equipotential terminal
is at the rear of the appliance. When the appliance is operating, the supplied voltage must not
deviate from the nominal voltage value of ±10%.
Mod. KCP5 96 V – KCP5 96 VS – KC 96 V – KC 96 VS – KC 96 M – KC 96 MS
- For access to
the terminal board, remove the rear panel of the appliance. Loosen the cable gripper and allow
the cable to pass through. Locate the conductors so that the earth cable is the last to detach
from its terminal in the event of reverse pulling. Connect the phase conductors on the terminals
marked “L1” and “L2”, the neutral conductor to the terminal marked “N”, and the earth
conductor to the terminal marked with symbol according to the following lay-out:
380 - 400V~ 2N
N L
2
L
1
(this electrical connection lay-out is also available near the power supply terminal board).
Tighten the cable gripper and re-fit the rear panel of the appliance. The appliance must be
connected to an unipotential system whose efficiency must be suitably verified according to
current legal regulations.
This connection must be made between different appliances using the terminal marked with
the symbol
. The unipotential conductor must have minimum diameter of 10 mm
2
. The
unipotential terminal is located low down at the rear of the appliance.
The power cable must comply with the following characteristics:
KCP96 V – KCP96 VS
KCR 96 V
KCP5 96 V – KCP5 96 VS – KC 96 V – KC 96 VS
KC 96 M – KC 96 MS
Power supply voltage (V~) 220 – 230 380 – 400 2N
Power cable diameter 3x1.5 mm
2
4x2.5 mm
2
Type of power cable H07RN-F
Safety device - The appliance is supplied with a manually resetting thermal breaker to protect
against excessive, dangerous temperatures which could be accidentally generated inside the
oven. If tripped, the device cuts out electrical power to the appliance. To access this device,
remove the panel at the rear of the appliance.
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hendi KC 96 M wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Hendi KC 96 M

Hendi KC 96 M Bedienungsanleitung - Deutsch - 26 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info