816328
13
Zoom out
Zoom in
Vorherige Seite
1/332
Nächste Seite
13
English
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously in
red.
When the battery becomes fully recharged, the pilot
lamp will blink in red. (At 1-second intervals) (See
Table 1)
Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or
the rechargeable battery.
Table 1
Indications of the pilot lamp (RED)
Before
charging
Lights on for
0.5 seconds and o
for 0.5 seconds
Blinks
Plugged into power
source
While
charging
Lights continuously
Lights
Charging
complete
Lights on for
0.5 seconds and o
for 0.5 seconds
Blinks
Overheat
standby
Lights on for
1 second and o for
0.5 seconds
Blinks
Battery overheated.
Unable to charge.
(Charging will
commence when
battery cools)
Charging
impossible
Lights on for
0.1 seconds and o
for 0.1 seconds
Flickers
Malfunction in
the battery or the
charger
Regarding the temperatures and charging time of the
battery.
The temperatures and charging time will become as
shown in Table 2.
Table 2
Charger
Battery UC18YFSL
Charging voltage V 14.4–18
Weight kg 0.5
Temperatures at which the battery
can be recharged 0°C–50°C
Charging time for battery
capacity, approx. (At 20°C)
1.5 Ah
2.0 Ah
2.5 Ah
3.0 Ah
4.0 Ah
5.0 Ah
6.0 Ah
8.0 Ah
min
min
min
min
min
min
min
min
22
30
35
45
60
75
90
120
Number of battery cells 410
NOTE
The recharging time may vary according to temperature
and power source voltage.
CAUTION
When the battery charger has been continuously used,
the battery charger will be heated, thus constituting
the cause of the failures. Once the charging has been
completed, give 15 minutes rest until the next charging.
4. Disconnect the charger’s power cord from the
receptacle.
5. Hold the charger rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might be
low when using them the rst and second time. This is a
temporary phenomenon, and normal time required for
recharging will be restored by recharging the batteries
2–3 times.
How to make the batteries perform longer.
(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery. If
you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the battery
and recharge it after it has cooled for a while.
CAUTION
If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used,
the pilot lamp of the charger lights for 1 second, does
not light for 0.5 seconds (o for 0.5 seconds). In such a
case, rst let the battery cool, then start charging.
When the pilot lamp ickers (at 0.2-second intervals),
check for and take out any foreign objects in the
charger’s battery connector. If there are no foreign
objects, it is probable that the battery or charger is
malfunctioning. Take it to your authorized Service
Center.
MOUNTING AND OPERATION
Action Figure Page
Removing and inserting the battery 5 2
Switch operation*172
Using the hook*244 6
Selecting accessories 323
*1 Switch operation
When the switch is engaged while sliding the lock-o
lever, the saw chain rotates. (Fig. 7)
Unless the lock-o lever is being slid, the switch cannot
be engaged.
00BookCS1825DCEU.indb1300BookCS1825DCEU.indb13 2022/12/0117:02:542022/12/0117:02:54
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hikoki CS1825DC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info