742721
11
Zoom out
Zoom in
Vorherige Seite
1/216
Nächste Seite
11
English
When the pilot lamp ickers in red (at 0.2-seconds
intervals), check for and take out any foreign objects in
the charger’s battery connector. If there are no foreign
objects, it is probable that the battery or charger is
malfunctioning. Take it to your authorized Service
Center.
Since the built-in micro computer takes about 3 seconds
to con rm that the battery being charged with chargers
are taken out, wait for a minimum of 3 seconds before
reinserting it to continue charging. If the battery is
reinserted within 3 seconds, the battery may not be
properly charged.
MOUNTING AND OPERATION
Action Figure Page
Removing and inserting the battery 2 2
Charging 3 2
Indicator lamp lights when battery
is low
43
Installing/Removing the side
handle
53
Inserting SDS-plus drilling tools 6 3
Removing SDS-plus drilling tools 7 3
Selecting rotation direction 8 4
Selecting the operating mode 9 4
Adjusting the drilling depth 10 4
Switch operation 11 4
Setting the speed 12 4
Auto stop function 13 4
How to use the LED light 14 5
Cleaning the battery installation
compartment and the battery
15 5
Selecting accessories* 208, 209
* For detailed information regarding each tool, contact a
HiKOKI authorized service center.
SELECT OPERATION MODE
Pressing the changeover switch allows the selection of
rotation speed and the auto stop function.
Rotation speed (Low mode/Normal mode) (Fig. 12)
Select either Low mode or Normal mode and operate the
tool in the selected speed.
Auto stop mode (on/o ) (Fig. 13)
This product is equipped with an auto stop function to
support continuous drilling work. The function features a
memory mode for storing the work time for drilling from
switch ON to switch OFF, and an auto stop mode that
automatically stops the motor from the second drilling
onward should the work exceed the stored work time
while the switch is ON.
AUTO STOP FUNCTION
In selection mode, pressing the button for longer than two
seconds will move to memory mode. (Fig. 13)
(At the same time the auto stop lamp will blink.)
Conduct drilling when the auto stop lamp is ashing. The
time between switching ON and switching OFF is stored by
the tool.
(At the same time, the auto stop lamp will light up.)
Conduct drilling when the auto stop lamp is ashing.
Continuous drilling is possible as the memory storage time
will be recorded by the tool until the auto stop function’s auto
stop mode is cancelled.
The auto stop function is cancelled by pressing the
changeover switch once again for over two seconds.
(At the same time, the auto stop lamp will switch o .)
CAUTION
Switch ON the tool once you place the tip of the tool on
the work material.
The rotation speed and the level at which the switch is
pulled during drilling is not stored to memory.
Fully carry out drilling in one go during auto stop mode.
The motor will stop even if you switch OFF within the
memory storage time.
When you switch OFF within the memory storage time,
the count will be reset. If you rework a task in which a
hole has been partially drilled, the memory storage time
will be fully recounted.
The auto stop function will remain active until canceled.
REACTIVE FORCE CONTROL
This product is equipped with a Reactive Force Control
(RFC) feature that reduces jerking of the tool body.
If the tool bit is suddenly overburdened, any jerking of the
tool body is reduced by activation of the slip clutch or by
stopping of the motor by the sensor built into the tool body.
If the motor is stopped because of overburdening detection
by the controller, the display lamp will blink while the switch
is pulled. In addition, the lamp will continue blinking for
approximately three seconds after the switch is released.
The motor will remain stopped while the lamp is blinking.
(Fig. 16)
Because the RFC feature may not activate or its performance
may be insu cient depending on the working environment
and conditions, be careful not to suddenly overburden the
tool bit while operating.
Possible causes of sudden overburdening
Tool bit biting into material
Impact against nails, metal or other hard objects
Tasks involving prying or any excess application of
pressure, etc.
Also, other causes include any combination of the
aforementioned.
When the reactive force control (RFC) is triggered
When the RFC is triggered and the motor stops, turn
o the tool’s switch and remove the cause of the
overburdening before continuing operation.
Fig. 16
0000Book_DH18DPA.indb 110000Book_DH18DPA.indb 11 2020/09/29 14:17:062020/09/29 14:17:06
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hikoki DH 18DPA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info