When the pilot lamp ickers (at 0.2-second intervals),
check for and take out any foreign objects in the charger’s
battery connector. If there are no foreign objects, it is
probable that the battery or charger is malfunctioning.
Take it to your authorized Service Center.
Since the built-in micro computer takes about 3 seconds
to con rm that the battery being charged with charger
is taken out, wait for a minimum of 3 seconds before
reinserting it to continue charging. If the battery is
reinserted within 3 seconds, the battery may not be
properly charged.
If the pilot lamp does not blink in red (every second)
even though the charger cord is connected to the power,
it indicates that the protection circuit of the charger may
be activated.
Remove the cord or plug from the power and then
connect it again after 30 seconds or so. If this does
not cause the pilot lamp to blink in red (every second),
please take the charger to the HiKOKI Authorized
Service Center.
MOUNTING AND OPERATION
Action Figure Page
Removing and inserting the battery 2 2
Charging 3 2
Selecting the mode 4 2
Tightening torque adjustment 5 2
Selecting the drill position 6 3
Selecting the impact position 7 3
Change rotation speed 8 3
How to use the LED light 9 3
Mounting the bit 10 3
Reversing the rotational direction 11 4
Switch operation 12 4
Removing and mounting the hook 13 4
Remaining battery indicator 14 4
Selecting accessories
98
LED LIGHT WARNING SIGNALS
This product features functions that are designed to protect
the tool itself as well as the battery. While the switch is
pulled, if any of the safeguard functions are triggered
during operation, the LED light will blink as described in
Table 3. When any of the safeguard functions are triggered,
immediately remove your nger from the switch and follow
the instructions described under corrective action.
Table 3
Safeguard Function LED Light Display Corrective Action
Overburden Protection
On 0.1 second/o 0.5 second
If the operating with the shift knob set on
HIGH, adjust to LOW and continue operation.
Remove the cause of the overburdening.
Temperature Protection
On 0.3 second/o 0.3 second
Allow the tool and battery to thoroughly cool.
MAINTENANCE AND INSPECTION
1. Inspecting the tool
Since use of as dull tool will degrade e ciency and
cause possible motor malfunction, sharpen or replace
the tool as soon as abrasion is noted.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure that
they are properly tightened. Should any of the screws be
loose, retighten them immediately. Failure to do so could
result in serious hazard.
3. Maintenance of the motor
The motor unit winding is the very “heart” of the power
tool. Exercise due care to ensure the winding does not
become damaged and/or wet with oil or water.
4. Cleaning on the outside
When the driver drill is stained, wipe with a soft dry cloth
or a cloth moistened with soapy water. Do not use chloric
solvents, gasoline or paint thinner, for they melt plastics.
5. Storage
Store the driver drill in a place in which the temperature
is less than 40°C and out of reach of children.
NOTE
Storing lithium-ion batteries.
Make sure the lithium-ion batteries have been fully
charged before storing them.
Prolonged storage (3 months or more) of batteries with
a low charge may result in performance deterioration,
signi cantly reducing battery usage time or rendering
the batteries incapable of holding a charge.
However, signi cantly reduced battery usage time may
be recovered by repeatedly charging and using the
batteries two to ve times.
If the battery usage time is extremely short despite
repeated charging and use, consider the batteries dead
and purchase new batteries.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
Important notice on the batteries for the HiKOKI
cordless power tools
Please always use one of our designated genuine
batteries. We cannot guarantee the safety and
performance of our cordless power tool when used with
batteries other than these designated by us, or when
the battery is disassembled and modi ed (such as
disassembly and replacement of cells or other internal
parts).
00Book_DS12DD.indb 1000Book_DS12DD.indb 10 2020/04/02 12:15:162020/04/02 12:15:16
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hikoki DS 12DD wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info