CAUTION
Wear a dust mask.
(1) Detach the dust box (Fig. 13)
(2) Clean out the dust in the cyclone chamber (Fig. 14)
(3) Clean out the dust in the lter chamber (Fig. 15)
In addition, clean o all dust attached to the surface of
the lter.
NOTE
Do not directly touch the lter with a hard brush or similar
tool, or blast the backside of the lter with compressed
air.
Also, do not wash the lter with water.
Doing so may scratch the lter and/or shorten its life.
(4) Make sure the lter is positioned correctly. (Fig. 16)
(5) Attach the dust box to the dust housing. (Fig. 17)
NOTE
Make sure there is no dust attached to the latch before
tting the latch.
Check to con rm that the latches on both sides are
securely engaged after attaching.
Failure to do so may result in the dust box falling o
during use.
MAINTENANCE AND INSPECTION
WARNING
When performing inspections or maintenance, be sure
to turn o the tool’s switch and remove the dust extractor
system from the tool body.
1. Inspecting the body of the dust extractor system
Regularly inspect the places where the various parts of
the dust extractor system t together to make sure there
is no rattling or loose parts.
If the dust extractor system is used while parts of it are
loose, there is a risk of injury or other accidents. If there
is anything abnormal with the dust extractor system,
consult the HiKOKI Authorized Service Center.
2. Cleaning on the outside
When the power tool is stained, wipe with a soft dry cloth
or a cloth moistened with soapy water. Do not use chloric
solvents, gasoline or paint thinner, for they melt plastics.
3. Replacing the nozzle seal and brush cap
As the nozzle seal and brush cap wear out, the dust
extracting performance declines.
If the nozzle seal or brush cap is worn out, replace it with
a new one.
(a) Replacing the nozzle seal (Fig. 18)
Remove the nozzle seal as shown in the gure.
Attach a new nozzle seal. Align the nozzle seal so that its
notch ts onto the outer shape of the nozzle.
(b) Replacing the brush cap (Fig. 19)
Use pliers or a similar tool remove the C-ring, and
replace the brush cap with a new one.
Align the groove of the new brush cap with the bump on
the nozzle and t them together.
Reattach the C-ring in its original position, making sure
that it is secure and won’t fall o .
4. Storage
 Store the power tool in a place in which the temperature
is less than 50°C and out of reach of children.
 When storing the dust extractor system, press the
nozzle adjustment button to put the nozzle in the fully
extended position. If unable to store with the nozzle fully
extended, the nozzle can be shortened to about half its
size (Fig. 20).
Keeping the nozzle fully contracted inside the dust
extractor system may result in its pressing force
becoming weaker.
 If the nozzle doesn’t return to the fully extended position,
pull it outward with your hand. Repeatedly extending and
contracting it will help it recover.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country speci c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.
NOTE
Due to HiKOKI’s continuing program of research and
development, the speci cations herein are subject to
change without prior notice.
00BookDustextractorsystem.indb1000BookDustextractorsystem.indb10 2022/10/1111:50:142022/10/1111:50:14
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hikoki DUST EXTRACTOR SYSTEM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info