816326
14
Zoom out
Zoom in
Vorherige Seite
1/332
Nächste Seite
14
English
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries and
batteries that have not been used for an extended period
is not activated, the electric discharge might be low when
using them the rst and second time. This is a temporary
phenomenon, and normal time required for recharging
will be restored by recharging the batteries 2–3 times.
How to make the batteries perform longer
(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery. If
you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate, and
the battery life will be shortened. Leave the battery and
recharge it after it has cooled for a while.
CAUTION
If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used, the
pilot lamp of the charger lights up green. In such a case,
rst let the battery cool, then start charging.
When the pilot lamp ickers in red (at 0.2-seconds
intervals), check for and take out any foreign objects in
the charger’s battery connector. If there are no foreign
objects, it is probable that the battery or charger is
malfunctioning. Take it to your authorized Service
Center.
Since the built-in micro computer takes about 3 seconds
to con rm that the battery being charged with charger
is taken out, wait for a minimum of 3 seconds before
reinserting it to continue charging. If the battery is
reinserted within 3 seconds, the battery may not be
properly charged.
If the pilot lamp does not blink in red (every second)
even though the charger cord is connected to the power,
it indicates that the protection circuit of the charger may
be activated.
Remove the cord or plug from the power and then
connect it again after 30 seconds or so. If this does
not cause the pilot lamp to blink in red (every second),
please take the charger to the HiKOKI Authorized
Service Center.
BEFORE USE
Action Figure Page
Removing and inserting the
battery 22
Charging 3 2
Selecting accessories 326
1. How to operate operation panel
(1) Power switch ON (See Fig. 4)
Under the condition of “Power switch OFF”, push and
hold on Power switch more than 1 second, then power
indicator lights in Green.
NOTE
Do not press the push lever and/or pull the trigger during
the process of turning the power switch ON.
Doing so will prevent the power switch from turning ON.
[Auto power o ]
When the power is turned on but the Nailer is not used
for 30 minutes, the Nailer is automatically turned o . To
turn on again, press the power switch.
WARNING
Never leave the Nailer with the power on. This could
result in an accident.
(2) Power switch OFF (See Fig. 4)
Under the condition of “Power switch ON”, push Power
switch, then power indicator goes o .
Under the condition of “Power switch ON”, functions
below are active.
(3) Select Nailing operation mode
(Single sequential actuation / Contact actuation)
After power switch turn ON, always set in Single
sequential actuation mode as initial. (Nailing operation
indicator light in blue.) (See Fig. 5)
To change nailing operation mode, push Nailing
operation switch once. Every pushing, mode will change
between “Single sequential” and “Contact”. (See Fig. 6)
Lighting (Blue):
SINGLE SEQUENTIAL ACTUATION MECHANISM,
Blinking (Blue):
CONTACT ACTUATION MECHANISM
(4) Remaining battery level
While power switch ON, the battery remaining level can
be checked by status of LED lamp as below.
Status of indicator
LED do not light
The battery remaining
power is enough.
LED (Red) blinks
The battery remaining
power is nearly empty.
LED (Red) lights
The battery remaining
power is empty.
Recharge the battery as
soon as possible.
NOTE
There are situations in which this product will not operate
when two LEDs are lit on the battery’s remaining battery
indicator.
This is not a malfunction but a control feature that is
speci c to this product. The tool will operate when the
battery is recharged.
0000BookNT1850DA.indb140000BookNT1850DA.indb14 2022/09/0814:44:592022/09/0814:44:59
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hikoki NT1850DA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info