Setting possibilities
a
b
33
33
Design:
•
Cost-effective amplifier design
•
Input-side level control to adjust to the HF
input level
•
Compact, built-in transformer power supply
unit with fixed plastic cover as touch guard.
33
33
Housing:
•
Removable lid with central bolt permits
user-friendly configuration
•
The die-cast base housing reduces the
component temperatures, enhancing the
unit's durability and reliability.
•
RF connections: F connectors
33
33
Meets EN 60065
EN 50083-1
EN 50083-2, class A
EN 50083-3 quality class 2
Description
The level control is adjusted as follows:
1. Remove the housing lid:
After slackening the central bolt (a) lift the lid
off by releasing the catch on the left-hand side
(b).The circuit board for adjustment of the level
control is now accessible.
GB
When this product has reached the end
of its useful life, it is to be turned in for
proper disposal as electronic refuse in
compliance with the current disposal regulations
of your respective city/country/state.
Recycling Information
CAUTION: Observe the safety requirements
of EN 50083 -1
33
33
Equipotential bonding
The complete system must be provided with
equipotential bonding by means of a
mechanically stable protective conductor with
a minimum cross-section of 4mm
2
. There is a
connection point at the earthing screw at the
right wall bracket.
NOTE: The unit must not be exposed to
dripping or splashing water.
Installation
Safety Requirements
33
33
Choose a location and orientation that will not
impair the convection cooling of the amplifier:
•
Vertical (cooling fins aligned vertically)
•
Uncovered on wall
•
Installed in a cabinet only in strict
conformance to the permissible ambient
operating temperature (measured in the air
stream underneath the amplifier)
33
33
Wall mounting
•
Fixed to brackets by appropriately sized
screws (dia. max. 4.8 mm)
•
Fixings 158 mm apart
Fig. 1
above