Version: 1.5
Portable Air Conditioner
2
Hisense Corporation
MODEL:
AP-05CR1SEJS1
AP-07CR1SEJS1
AP-09CR1SEJS
AP-10CR1SEJS
AP-14DR1SFJS2
AP-13HR1SGRS00
AP-08CR1SHQS00
AP-10CR1SGRS00
AP-10CW1SGRS00
AP-12CR1SGRS00
AP-14CR1SFTS00
AP-14DR1SFTS02
AP-12CR1SEJS
AP-12CR4SFJS1
AP-14HR1SFTS00
AP-12CR4SFMS00
AP-09CR4SFMS01
AP-12CR4RFJS00
+AP-09HR4GFMS01
+AP-12HR4GFMS00
+AP-09CR4GFMS00
+AP-12CR4GFMS00
+AP-09CR4GEJS00
+AP-09CR4GEPS00
AP-12HR4SEJS00
+AP-09HR4GFTS01
+AP-12CR4GFJS00
+AP-09HR4GFJS01
+AP-09CR4GELS00
+AP-09HR4GFLS01
+AP-12CR4GFLS00
+AP-12HR4GFJS00
NOTE:
The letterJ、“L”、“P 、“Min model is code of front panel. In one model, the
code can be show as “J、“L”、“P 、“M.
3
Contents
1. Safety Considerations ................................................................................................................................... 4
2. Product Specifications ................................................................................................................................... 6
3. Product Picture and Drawing ...................................................................................................................... 16
3-1. Product Pictures ................................................................................................................................ 16
3-2. Product dimensions .......................................................................................................................... 30
4. Installation Instruction ................................................................................................................................ 19
4-1. Installation Instruction...................................................................................................................... 19
4-2. Electric Wiring Diagram .................................................................................................................... 25
4-3. Refrigerant Flow System ................................................................................................................... 28
4-4. Test Running ...................................................................................................................................... 29
5. Function Operation ..................................................................................................................................... 30
5-1. Operation Range (cooling and heating......................................................................................... 30
5-2. Remote Controller Operation & Function ........................................................................................ 30
5-3. Function Instruction .......................................................................................................................... 31
6. Electrical Characteristics.............................................................................................................................. 38
6-1. Print Circuit Board ............................................................................................................................. 38
6-2. Temperature Sensor ......................................................................................................................... 41
7.Trouble Shooting........................................................................................................................................... 43
7-1.Trouble Shooting ................................................................................................................................ 43
7-2. Error Code Table................................................................................................................................ 44
4
1. Safety Considerations
IMPORTANT!
Please Read Before Starting
This air conditioning system meets strict safety and operating standards. As the installer or service
person, it is animportant part of your job to install or service the system, so it operates safely and
efficiently.
For safe installation and trouble-free operation, youmust:
Carefully read this instruction booklet before beginning.
Follow each installation or repair step exactly asshown.
Observe all local, state, and national electrical codes.
Pay close attention to all warning and caution noticesgiven in this manual.
This symbol refers to a hazard or unsafe practice whichcan result in severe
personalinjury or death.
This symbol refers to a hazardor unsafe practice which canresult in personal
injury orproduct or property damage.
If Necessary, Get Help
These instructions are all you need for most installationsites and maintenance conditions. If you
require help fora special problem, contact our sales/service outlet oryour certified dealer for
additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible forimproper installation or maintenance service,
includingfailure to follow the instructions in this document.
SPECIAL PRECAUTIONS
When Wiring
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY
AQUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THISSYSTEM.
Do not supply power to the unit until all wiring and tubing are completed or reconnected and
checked.
Highly dangerous electrical voltages are used in thissystem. Carefully refer to the wiring diagram
andthese instructions when wiring. Improper connectionsand inadequate grounding can cause
accidentalinjury or death.
Ground the unit following local electrical codes.
Connect all wiring tightly. Loose wiring may causeoverheating at connection points and a possible
5
firehazard.
When Transporting
Be careful when picking up and moving the indoor andoutdoor units. Get a partner to help, and
bend yourknees when lifting to reduce strain on your back. Sharpedges or thin aluminum fins on
the air conditioner cancut your fingers.
When Servicing
Turn the power OFF at the main power box (mains)before opening the unit to check or repair
electrical parts and wiring.
Keep your fingers and clothing away from any movingparts.
Clean up the site after you finish, remembering tocheck that no metal scraps or bits of wiring
have been left inside the unit being serviced.
Others
Ventilate any enclosed areas when installing or testingthe refrigeration syst em. Escaped
refrigerant gas, oncontact with fire or heat, can produce dangerouslytoxic gas.
Confirm upon completing installation that no refrigerant gas is leaking. If escaped gas comes in
contactwith a stove, gas water heater, electric room heater orother heat source, it can produce
dangerously toxicgas.
NOTE:
The figure
size and parameter of the product may not be identical with the service manual, please
take the actual product as the standard.
6
2. Product Specifications
Model No.
AP-05CR1SEJS1
AP-07CR1SEJS1
AP-10CR1SEJS
Type
C/O
C/O
C/O
Ratings
Cooling Capacity
W
1465
2052
2930
Heating Capacity
W
/
/
/
Input-Cooling
W
580
835
1160
Input-Heating
W
/
/
/
Rated Input-Cooling
W
/
/
/
Rated Input-Heating
W
/
/
/
Air Circulation
CMH
Max
320
320
340
EER for Cooling
W/W
2.52
2.46
2.53
COP for Heating
W/W
/
/
/
Refrigerant
/
/
R410A
Refrigerant charge
volume
g
310
430
500
Indoor Unit Noise
Level
High(dB
(A))
55
55
55
Low(dB
(A))
52
52
52
Outdoor Unit Noise
Level
dB (A)
/
/
/
Power Supply
Voltage, Frequency,
Phase
115V~,60Hz,1P
115V~,60Hz,1P
115V~,60Hz,1P
Current
Cooling
(A)
6
7.5
10.6
Heating
(A)
/
/
/
Rated Current
Cooling
(A)
/
/
/
Heating
(A)
/
/
/
LRA
A
/
/
36
System
Compressor type
Rotary
Rotary
Rotary
Compressor Model
No.
39B131AA&54KA
39A171AD&5DKB
39A201AD&59KB
Compressor MFG
RECHI
RECHI
RECHI
Expansion Device
Capillary
Capillary
Capillary
Evaporator
Copper tube and
Aluminum Fin
Copper tube and
Aluminum Fin
Copper tube and
Aluminum Fin
7
Condenser
Copper tube and
Aluminum Fin
Copper tube and
Aluminum Fin
Copper tube and
Aluminum Fin
Features
Display on Front
Panel
Yes
Yes
Yes
LCD Wireless Remote
Controller
Yes
Yes
Yes
Removable and
washable Panel
NA
NA
NA
Washable PP Filter
Yes
Yes
Yes
24 Hours Timer
Yes
Yes
Yes
3 Speed and Auto
Indoor Fan Control
Yes
Yes
Yes
Vertical Auto Swing
Louver
Yes
Yes
Yes
Manual Adjustable
Horizontal Swing
Louver
NA
NA
NA
Sleep Operation
Yes
Yes
Yes
Smart Function
Yes
Yes
Yes
Super Function
Yes
Yes
Yes
Auto Restart
Yes
Yes
Yes
Other
Net Dimensions
WxHxD (mm)
Indoor
Unit
430x695x325
430x695x325
430x695x325
Outdoor
Unit
/
/
/
Net Weight (Kg)
Indoor
Unit
22.5
24.5
27
Outdoor
Unit
/
/
Packing Dimensions
WxHxD (mm)
Indoor
Unit
480x880x380
480x880x380
480x880x380
Outdoor
Unit
/
/
/
Gross Weight (Kg)
Indoor
Unit
30
31.9
32
Outdoor
Unit
/
/
/
Model No.
AP-14DR1SFJS2
AP-14DR1SFTS02
Type
H/C
Ratings
Cooling Capacity
W
4103
Heating Capacity
W
/
8
Input-Cooling
W
1350
Input-Heating
W
1350
Rated Input-Cooling
W
/
Rated Input-Heating
W
/
Air Circulation
CMH Max
473
EER for Cooling
W/W
3.04
COP for Heating
W/W
/
Refrigerant
R410A
Refrigerant charge
volume
g
640
Indoor Unit Noise Level
High(dB (A))
55( Sound pressure )
Low(dB (A))
53( Sound pressure )
Outdoor Unit Noise
Level
dB (A)
/
Power Supply
Voltage, Frequency,
Phase
115V~,60Hz,1P
Current
Cooling (A)
11.8
Heating (A)
12
Rated Current
Cooling (A)
/
Heating (A)
/
LRA
A
50.5
System
Compressor type
Rotary
Compressor Model No.
44A261AG&FJKC
Compressor MFG
RECHI
Expansion Device
Capillary
Evaporator
Copper tube and
Aluminum Fin
Condenser
Copper tube and
Aluminum Fin
Features
Display on Front Panel
Yes
LCD Wireless Remote
Controller
Yes
Removable and
washable Panel
NA
Washable PP Filter
Yes
24 Hours Timer
Yes
3 Speed and Auto
Indoor Fan Control
Yes
Vertical Auto Swing
Louver
Yes
Manual Adjustable
Horizontal Swing
Louver
NA
Sleep Operation
Yes
9
Smart Function
Yes
Super Function
Yes
Auto Restart
Yes
Other
Net Dimensions
WxHxD (mm)
Indoor Unit
442x750x382
Outdoor
Unit
/
Net Weight (Kg)
Indoor Unit
34
Outdoor
Unit
/
Packing Dimensions
WxHxD (mm)
Indoor Unit
505x885x430
Outdoor
Unit
/
Gross Weight (Kg)
Indoor Unit
39
Outdoor
Unit
/
Hisense Model
AP-14CR1SFTS00
AP-14DR1SFTS00
AP-14HR1SFJS00
AP-14HR1SFTS00
Refrigerant type
R410A
R410A
R410A
R410A
Gas charge
22.5oz
22.5oz
22.5oz
0.605kg
Unit Specifications and Performance
Ratings
BTU - Cool(SCC)
14,000
14,000
14,000
14,000
BTU - Heat(Watts)
NO
1350W
11000BTU
12,000
Energy Efficiency Rating;
Cooling(SCE)
10
10
10
9.1 W/W
Energy Star
No
No
No
No
Heating Rating Conditions
N/A
N/A
N/A
3
Design pressure high side (PSIG)
600
600
600
4.15 MPa
Design pressure low side (PSIG)
236
236
236
1.6 MPa
Cooling Rating Conditions
ASHRAE-128-2001
ASHRAE-128-2001
ASHRAE-128-2001
ASHRAE-128-2001
Sound (dBA High)
53
53
54
54
Sound (dBA Medium)
52
52
53
/
Sound (dBA Low)
51
51
52
51
Air Features
Air Flow on High (CFM)
278
278
278
278
Air Flow on Medium (CFM)
237
237
237
237
Air Flow on Low (CFM)
204
204
204
204
System
Compressor Type
Rotary
Rotary
Rotary
Rotary
Brand
RECHI
RECHI
RECHI
LG
Compressor
44A261AG&FJKC
44A261AG&FJKC
44A261AG&FJKC
GKN110CAA
Expansion Device
capillary tube
capillary tube
capillary tube
capillary tube
10
Evaporator
Copper tube and blue
aluminum fins
(hydrophilic)
Copper tube and
blue aluminum fins
(hydrophilic)
Copper tube and
blue aluminum fins
(hydrophilic)
Copper tube and
blue aluminum fins
(hydrophilic)
Condenser
Copper tube and
aluminum fins (bare)
Copper tube and
aluminum fins
(bare)
Copper tube and
blue aluminum fins
(hydrophilic)
Copper tube and
blue aluminum fins
(hydrophilic)
Features
Unit Control type
Electronic
Electronic
Electronic
Electronic
Fan Control
Button
Button
Button
Button
Thermostat Control
Button
Button
Button
Button
Display Type
LED
LED
LED
LED
Sleep Mode
Yes(on the controller)
Yes(on the
controller)
Yes(on the
controller)
Yes(on the
controller)
Dry Mode (auto speed only)
Yes
Yes
Yes
Yes
Water Full Indicator
Yes
Yes
Yes
Yes
Auto Cool (auto fan in cooling)
Yes(on the controller)
Yes(on the
controller)
Yes(on the
controller)
Yes(on the
controller)
Smart Mode (remote access)
Yes(on the controller)
Yes(on the
controller)
Yes(on the
controller)
Yes(on the
controller)
Rapid Cool(Jet) Mode (lowest
temp & high speed) - Remote only
Yes(on the controller)
Yes(on the
controller)
Yes(on the
controller)
Yes(on the
controller)
Fan Only
Yes - 3 Speed
Yes - 3 Speed
Yes - 3 Speed
Yes - 3 Speed
Anion
NO
NO
NO
NO
Cooling Speed Selections
3
3
3
3
Timer- (24 Hr On/Off)
Yes- (24 Hr on/off - 10
minutes Increments up
to 24 Hrs)
Yes- (24 Hr on/off -
10 minutes
Increments up to
24 Hrs)
Yes- (24 Hr on/off -
10 minutes
Increments up to
24 Hrs)
Yes- (24 Hr on/off -
10 minutes
Increments up to
24 Hrs)
Clock
on the remote controller
on the remote
controller
on the remote
controller
on the remote
controller
Air Swing (Motorized - Upward &
Downward Motion)
Yes
Yes
Yes
Yes
Auto-Restart
Yes
Yes
Yes
Yes
Room Temperature Display
Units (F or C) factory default
Yes
Yes
Yes
Yes
Fahrenheit to Celsius
function
Yes
Yes
Yes
Yes
Vent System
Single Duct
Single Duct
Single Duct
Single Duct
Electrical information
Volts
115
115
115
115
Frequency (Hz)
60
60
60
60
Amps (Cooling)
11.8
11.8
11.8
12
Watts (Cooling)
1350
1350
1350
1370
L.R.A of compressor (A)
50.5
50.5
50.5
52
Fuse Size (Amps)
15
15
15
15
11
Power Cord Length - Cabinet
to Wall
4ft.
4ft.
4ft.
4ft.
Power Cord Color
Black
Black
Black
Black
Power Plug Type (AMP/Plug)
LCDI(5-15P)
LCDI(5-15P)
LCDI(5-15P)
LCDI(5-15P)
Unit Exterior Cabinet Dimensions
Height (mm)
750
750
750
750
Width (mm)
443
443
443
443
Depth (mm)
375
375
375
375
Weight
Net Weight (kg)
35.8
36.3
36.8
36.8
Shipping Weight (kg)
38.8
39.3
39.8
39.8
Filter information
Carton Height (mm)
890
890
890
890
Carton Width (mm)
500
500
500
500
Carton Depth (mm)
425
425
425
425
Loading Capacity (40' HC
Container)
374
374
374
374
Hisense Model
AP-08CR1SHQS00
AP-10CR1SGRS00
AP-10CW1SGRS00
AP-12CR1SGRS00
AP-13HR1SGRS00
Refrigerant type
R410A
R410A
R410A
R410A
Gas charge
11.66 Oz
16.23oz
16.93oz
16.93oz
Unit Specifications and
Performance
Ratings
BTU - Cool(SCC)
8000 Btu/hr
10,000
12,000
12,500
BTU - Heat(Watts)
NO
NO
NO
10500BTU
Energy Efficiency
Rating; Cooling(SCE)
8.8
8.2
8.2
8.6
Energy Star
No
No
No
No
Heating Rating
Conditions
N/A
N/A
N/A
N/A
Design pressure high side
(PSIG)
600
600
600
600
Design pressure low side
(PSIG)
236
236
236
236
Cooling Rating
Conditions
35/28.3
ASHRAE-128-2001
ASHRAE-128-2001
ASHRAE-128-2001
Sound (dBA High)
53
49
49
52
Sound (dBA Medium)
N/A
48
48
51
Sound (dBA Low)
51
47
47
50
Air Features
Air Flow on High (CFM)
194
205
195
205
Air Flow on Medium
(CFM)
N/A
180
170
180
Air Flow on Low (CFM)
170
160
150
160
20
Room Temperature Display Units
(F or C) factory default
Yes
Yes
Yes
Yes
Fahrenheit to Celsius
function
Yes, Push
Thermostat up
and down
buttons at same
time
Yes, Push
Thermostat up
and down buttons
at same time
Yes, Push
Thermostat up
and down
buttons at same
time
Yes, Push
Thermostat up and
down buttons at
same time
Vent System
Single Duct
Single Duct
Single Duct
Single Duct
Electrical information
Volts
220-240
220-240
220-240
220-240
Frequency (Hz)
50
50
50
50
Amps (Cooling/Heating)
4.7
4.3/4.0
5.9
6.0/5.2
Watts (Cooling/Heating)
1075/-
985/890
1340/-
1345/1070
L.R.A of compressor (A)
20.4
20.4
24.4
24.4
Fuse Size (Amps)
16A
16A
16A
16A
Power Cord Length -
Cabinet to Wall
2m
2m
2m
2m
Power Cord Color
white
white
white
white
Power Plug Type
(AMP/Plug)
CE-502N(16A)
CE-502N(16A)
CE-502N(16A)
CE-502N(16A)
Unit Exterior Cabinet
Dimensions
Height (in)
/
/
/
/
Height (cm)
74.4
74.4
74.4
74.4
Width (in)
/
/
/
/
Width (cm)
44.8
44.8
44.8
44.8
Depth (in)
/
/
/
/
Depth (cm)
40
40
40
40
Weight
Net Weight (lb)
/
/
/
/
Net Weight (kg)
34.0
35.0
36.0
36.0
Shipping Weight (lb)
/
/
/
/
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hisense AP-12CR4GFMS00 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info