Names of parts and their functions (Fig.1)
Cover
Keeps the cotton puff set on the head.
Head
Set a cotton puff.
Side plate
There is no effect unless either of
the right or left plate is touched.
Main body socket
Batteries (built-in)
Two nickel-hydrogen batteries
Power switch (" ")
When this switch is pressed, it turns "ON"
and the indication lamp of the level stored
in the memory flashes. When this switch is
pressed again, it turns "OFF."
After an elapse of three minutes,
an automatic stop will be made.
Level indication lamp (Orange)
This lamp flashes/lights in 4 stages
according to the potential level.
"LEVEL" Select button
Every time this button is pressed,
the potential "LEVEL" changes over.
<Operation panel>
Vibration button (" ")
Switches the ON-OFF state of vibration.
Charge lamp (Red)
This lamp:
lights during charge, turns off after
completion of charge, stays out during
operation, and flashes to indicate recharge.
Main body
Rear side
Vibration lamp (Green)
This lamp lights when vibration is ON.
Charger (Model: KH-182B)
Device plug
Cord
Power plug
Insert completely.
Wetting
prohibited
Unplug
What is ion cleansing?
About the memory function
This device is equipped with a memory function for storing the potential level
(1 - 4) and vibration ON/OFF in the memory.
The potential level (1 - 4) and vibration ON/OFF immediately before an automatic stop
or turning off the switch are stored in the memory.
The settings can be changed by button selection during use.
If the batteries weaken, the memory function may be reset.
Positive potential Dirt Horny layer of skin
Negative potential
Never insert or remove the power plug in/from the outlet with wet hands.
(Cause of a failure or short circuit)
Never wash this product with water.
And, never soak in water or splash water on this product.
(Cause of a failure or short circuit)
Use with wet
hands prohibited
Never use, charge or leave this product in places splashed with water or in
damp places, such as in a bathroom. (Cause of a failure or short circuit)
Disassembly
prohibited
Never modify this product. Only a qualified technician may make repairs.
(Cause of a fire, electric shock, injury, or failure)
Check the head for any damage or deformation before use.
(Cause of skin damage)
Never use this product together with other beauty treatment devices at the
same time. (Cause of a failure or trouble)
Prohibited
Use only the attached charger. And, do not charge any other product
with the attached charger. (Possibility of an electric shock or ignition)
Never use this product if there is some injury or wound to your skin.
(Cause of skin trouble or pain)
Do not drop this product, or give it a strong impact.
(Cause of injury or a failure)
Do not wipe with benzine, thinner or alcohol, and do not spray insecticide.
(Cause of cracking, an electric shock, or ignition)
Make sure
Remove accessories such as earrings and necklaces, and contact lenses for
use. (Cause of an accident or trouble)
If there is any severe skin disorder or irregularity on your skin surface, or due
to downy hair, you may feel strong irritation in rare instances. In this case,
avoid using this product on that region. (Cause of an accident or trouble)
Do not keep the cotton puff on one part of your skin but always keep it in
motion. (Cause of skin trouble or poor physical condition)
Pull out the power plug and device plug without holding the cord.
(Cause of disconnection, an electric shock, short circuit, or ignition)
Make sure to pull out the power plug from the outlet unless used.
(Cause of an electric shock or fire by deterioration)
Protective cap
For protection during transportation.
Make sure to remove protective cap
before use.
By using the properties of electricity, dirt that is hard to remove by normal face washing
is drawn out from pores. Dirt in the air, dead skin cells, sebum, makeup components, etc.
Negatively charged fine dirt is drawn out by making the cleansing device side into a
positive potential. (Fig.2)
Makeup cannot be removed.
Image view
Use prohibited
in wet areas
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hitachi NC-5610 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info