15
setup extremely sensitive control surfaces for the expert pilot by extending the servo travel range. Adjustment of any one
channel can be adjusted from 0% (no servo movement) to 125% of normal servo travel. Normal servo travel is considered to be
30 degrees each side of center for a total servo range of 60 degrees. The factory default setting for each of the available EPA
s
is 100% of normal servo travel. You may program up to 125% of normal servo travel under EPA.
To enter into the EPA function from the normal power ON mode of the transmitter, simply follow the procedure below:
1. Depress both the UP and DN/TIMER keys simultaneously.
2. The LCD display should change to the MAIN EDIT MODE menu and you should see the EPA
function on the screen.
3. Use the Channel 4 trim key to change channel selection.
4. Use the Channel 1 key to increase or decrease the value of your End Point.
5. To exit this menu at any time, depress both the UP and DN/TIMER keys simultaneously once again.