518339
5
Zoom out
Zoom in
Vorherige Seite
1/39
Nächste Seite
9
Error messages
Worth knowing about blood pressure measurement
Blood pressure measurements should be performed in quiet and comfortable surroundings
as measurements can be affected by high or low temperatures. The blood pressure should
be measured at normal body temperatures.
Do not move or speak during measurement. Keep your feet flat on the floor.
Do not touch the cuff or the blood pressure device during measurement.
To obtain the best possible measurement, the blood pressure should be measured at
approximately the same time every day, and on the same arm.
If you are to perform several successive measurements, please wait 5 minutes between each
measurement.
The measurements are for guidance only. If you have doubts about your blood pressure,
consult your doctor.
The blood pressure device automatically deflates when the pressure exceeds 300 mmHg.
The product is not suited for persons suffering from arrhythmia (heart rhythm disturbances).
Measurement errors may occur if the user suffers from diabetes, poor blood circulation,
kidney problems, or has suffered a stroke.
Risk category indicator
The device complies with the blood pressure standard which classifies blood pressures into 6
grades. This innovative blood pressure classification shows with a symbol on the display the
presumed risk category for each measurement. The symbols and the classifications follow the
numbers in the table on page 3.
3. When “0” flashes on the display, the device is ready for
measurement and will automatically inflate the cuff to start
the measurement.
4. As soon as the systolic pressure has been established,
deflation will commence automatically and the diastolic
pressure is measured.
NOTE that the cuff is automatically re-inflated if the
device determines that the body requires higher pressure
to complete the measurement.
5. When the measurement is completed, the cuff automatically deflates and the display will show
the systolic pressure, the diastolic pressure, and the pulse. The measurement is
simultaneously stored in the monitor’s memory.
6. The device automatically switches off approximately 1 minute after use but can also be
switched off manually by pressing START/STOP.
7. If necessary, a measurement can be interrupted by pressing START/STOP (recommended) or
any other button on the device. The cuff will subsequently deflate immediately.
Description of the display
8
GB
GB
6
User 1: Shows that the device is employed by user 1.
User 2: Shows that the device is employed by user 2.
Low battery symbol. Shows on the display when a change of battery is required.
Pulse symbol. Shows pulse beats per minute.
IHB
Heart arrhythmia (heart rhythm disturbance): Indicated that arrhythmia has been established.
Read more about this in the section “Establishing arrhythmia (heart rhythm disturbances)”.
AVG. 3
Memory - average measurements. Shows the aerage of the 3 most recent measurements.
Risk category indicator: Compares measurements with the different blood pressure categories.
Read more about this in the section “Risk category indicator”.
Measurement error: Repeat measurement. Make sure that the cuff is properly fitted and keep
arm steady while measurement is taken.
Airflow error during inflation. Make sure that the cuff is properly fitted and perform
new measurement.
Pressure exceeds 30 mmHg. Switch off the device and switch on again.
Perform new measurement.
Data error. Remove the batteries and re-insert them.
Recalibration warning. It is recommended to have the device recalibrated. Read more about
this in the section “Calibration”.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Homedics BPA-200 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info