55
8.11 Setting the offset values for the individual
actuator "OFF"
If multiple actuators on various heaters are controlled by the
same controller, the heating of the individual heaters may be
uneven. This may be because of a severe non-uniform valve
flow between the valves and/or poorly dimensioned heaters. The
effect may possibly be able to be rectified with more (positive
offset) or less (negative offset) heating on individual heaters.
Call up special function "OFF" to make the setting and confirm
with the "OK" button.
Use the setting dial to select the desired actuator and confirm
with the "OK" button. Use the setting dial to set an offset value of
0-25% for the selected actuator. Confirm the entry with the "OK"
button.
8.12 Setting the set ventilation temperature
(Window open temperature) "WOT"
You can set the temperature for the individual sensors, which
should be attained when an open window is detected.
Call up special function "WOT" and confirm with the "OK" but-
ton.
The number of the sensor for which the window open tempera-
ture should be changed, the symbol for an open window and the
defined window open temperature are shown on the display.
Now choose the desired sensor using the setting dial. Confirm
with the "OK" button and set the window open temperature for
the selected sensor.