LA TENSION N’ARRIVE PAS À LA PRISE C.A. (13.1):
NON
NON
NON
NON
NON
NON
NON
NON
NON
NON
NON
OUI
OUI
OUI
OUI
OUI
OUI
OUI
OUI
OUI
OUI
OUI
L’INTERRUPTEUR DE PROTECTION EST-IL ACTIVÉ? ACTIVER
LA TENSION DEMANDÉE EST-ELLE SELECTIONNÉE SUR LE COMMUTATEUR? ⊗ SÉLECTIONNER
LES CÂBLAGES DU CADRE SONT-ILS EN BON ÉTAT? RÉTABLIR
LE CONDENSATEUR EST EN BON ÉTAT
⊗⊗ REMPLACER
LA TENSION MANQUE-T-ELLE ENCORE SI L’ON EXCITE LE CONDENSATEUR AUX
CONNECTEURS AVEC UNE BATTERIE DE 12 V? ⊗⊗
GÉNÉRATEUR OK
AMENER LE GÉNÉRATEUR AU SERVICE APRÈS-VENTE LE PLUS PROCHE
LE STARTER EST-IL ACTIONNÉ? ⊗⊗⊗
ACTIONNER
Y A-T-IL DE L’HUILE DANS LE MOTEUR?
REMPLIR
LA BOUGIE EST-ELLE RELIÉE? ⊗⊗⊗
RELIER
AMENER LE GÉNÉRATEUR AU SERVICE D’ASSISTANCE LE PLUS PROCHE
Y A-T-IL DU CARBURANT DANS LE RÉSERVOIR?
FAIRE LE PLEIN
LE ROBINET DU RÉSERVOIR EST-IL OUVERT? ⊗
OUVRIR
Y A-T-IL DE L’AIR DANS LE CIRCUIT D’ALIMENTATION? ⊗⊗
ÉLIMINER
LE MOTEUR NE DÉMARRE PAS (15.1):
⊗
SEULEMENT LÀ OÙ PRÉVU
⊗⊗
SEULEMENT POUR LES MOTEURS DIESEL
⊗⊗⊗
SEULEMENT POUR LES MOTEURS À EXPLOSION
⊗
SEULEMENT LÀ OÙ PRÉVU
⊗⊗
SEULMENT GÉNÉRATEURS MONOPHASE
DÉTECTION DES PANNES (SECTION DE LA SOUDEUSE MOBILE)
ABSENCE DE TENSION VERS LA PRISE C.A. ET/OU AUX PRISES DE SOUDURE (14.2):
NON
NON
NON
NON
OUI
OUI
OUI
OUI
LE DISJONCTEUR-PROTECTEUR EST-IL ACTIVÉ?
ACTIVER
RÉTABLIR
REMPLACER
SOUDEUSE MOBILE OK
LES CÂBLAGES DU TABLEAU DE DISTRIBUTION SONT-ILS EN BON ÉTAT?
LES CONDENSATEURS SONT-ILS EN BON ÉTAT?
LE REDRESSEUR EST-IL EN COURT-CIRCUIT?
PORTER LE GROUPE ÉLECTROGÈNE AU SERVICE ASSISTANCE LE PLUS PRÈS