DISPOSAL
Please do not dispose of this product in the household
waste at the end of its useful life. Disposal can take
place at your local retailer or at appropriate collection
points provided.
This regulation is valid only in EU member states.
CONDITION OF PURCHASE
As condition of purchase the purchaser assumes responsibility for
the correct use and care of this KAZ product according to these user
instructions. The purchaser or user must himself or herself decide
when and for how long this KAZ product is in use.
WARNING: IF PROBLEMS ARISE WITH THIS KAZ PRODUCT, PLEASE
OBSERVE THE INSTRUCTIONS IN THE GUARANTEE CONDITIONS. DO NOT
ATTEMPT TO OPEN OR REPAIR THE KAZ PRODUCT YOURSELF, AS THIS
COULD LEAD TO TERMINATION OF THE GUARANTEE AND CAUSE DAMAGE
TO PERSONS AND PROPERTY.
TECHNICAL MODIFICATIONS RESERVED
BH860E / BH862E
220-240V~
50Hz 46W
12. IMPORTANT: Should the water level in the atomization
chamber
15
extend beyond the uppermost sensor float, the
unit will interrupt the atomization process. In this case, switch
the unit off, check the correct fit of the float with its sealing
rubber, scoop out the atomizing chamber with a small vessel,
and put the unit back into operation.
CLEANING
We recommend that you clean the unit once a week.
1. Pull the power plug before cleaning.
2. Remove the tank lid
4
, the atomizer nozzle
3
, and the
decalcifying filter
6
.
3. Empty the residual water before cleaning.
4. Remove the float by means of its handle and clean the float.
5. Fill approx. one half of the water tank
5
with water(the
atomizing chamber
15
is automatically filled as well).
To assist the cleaning action, we recommend that you
add approx. 10 drops of Dimanin A* (do not add soap or
detergents).
After cleaning the water tank with a brush or a soft cloth,
flush it well and remount the float.
* “DIMANIN A” IS A CHLORINEFREE DISINFECTANT THAT IS ALSO
USED IN SWIMMING POOLS.
CAUTION: KEEP OUT OF THE REACH OF CHILDREN, DO NOT
SWALLOW! AVOID DIRECT EYE CONTACT! IN THE RECOMMENDED
DILUTION, IT IS NEITHER HARMFULL TO THE SKIN NOR TO THE
EYES.
6. Now replace the decalcifying filter, fill the unit with the
water, and replace the tank lid and the atomizer nozzle.
7. Connect the unit to the power supply and put into operation.
8. In addition to the weekly cleaning, you should carry out the
following procedure every 6 weeks at the latest:
Remove the decalcifying filter from the unit and briefly put it
in hot, not boiling, water (approx. 7C) in order to counteract
any formation of germs.
If the air filter is soiled,open the air-filter flap, dust it,
and replace. In case of heavy soiling, the air filter must be
exchanged (available from your dealer).
CHECKING THE WATER HARDNESS
Please check your water hardness (total hardness) with the
enclosed test strips as follows:
Dip the strip with all its test zones into a glass filled with fresh tap
water (do not hold under running water!). After 2 minutes, you
can determine the degree of hardness of your tap water according
to the following table.
No. of test zones
Green Violet Total Hardness
4 0 under 3º dH
3 1 4-7º dH
2 2 8-15º dH
1 3 16-22º dH
0 4 over 23º dH
To determine the value more precisely, you can also enquire at
your local waterworks.
The decalcifying filter enclosed can be used for water hardnesses
of up to 15˚ dH. The useful life of the decalcifying filter depends
on the hardness of the water, and it must be exchanged
accordingly:
useful life for 0-10˚ dH: approx. 5 months
useful life for 10-15˚ dH: approx. 3 months
If the unit is put out of operation for a longer period of time (e.g.
after the summer interval), the decalcifying filter must also be
newly exchanged.
With extreme grades of watter, an additional filter must be used,
of which there are 2 kinds:
K FILTERserves to pre-soften the water. It prolongs the useful
life of the standard decalcifying filter to approx. 2-3 months.
A FILTER is connected in series with the K-filter if salt content
is high. The additional filters are renewable and thus have a long
useful life.
IMPORTANT NOTE: IF A USEDUP DECALCIFYING FILTER IS USED, OR IF
AN ADDITIONAL. FILTER IS NOT USED, MINERALS MAY BE EMITTED THAT
APPEAR AS WHITE DEPOSITS IN THE ROOM.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Honeywell B H-862E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info