USE & OPERATION (CONTINUED)
LOW WATER ALARM (CONTINUED)
CLEANING & DRAINING THE WATER TANK
Move the unit to a location where the water can be drained. Remove the cap from the Drain plug
located at the bottom of the unit. Allow the tank to empty.
Refill the water tank with clean water, up to the maximum level and drain it completely.
Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive
elements or chemicals to clean this product.
When the product is not in use, store the unit in a dry place out of direct sunlight.
t
t
t
t
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect from the electrical socket.
Below are instructions on how to clean and maintain your air cooler. If the cooler will not be used for a
long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the
separate Safety & Maintenance Guide.
CLEANING THE CARBON DUST FILTER* AND HONEYCOMB COOLING MEDIA
The appliance is supplied with a Carbon Dust Filter* &
Honeycomb Cooling Media.
The Carbon Dust Filter* and Honeycomb Cooling Media are
located inside the Rear Grill. See Figure 1 for instructions on
how to remove them from the unit for cleaning and
maintenance.
Do not run the unit in COOL mode with stale water in the
tank. You must empty the water tank and refill with fresh
water, especially if the tank has not been cleaned in a long
time.
The cleaning frequency for the Honeycomb media depends
on local air and water conditions. In areas where the mineral
content of water is high, mineral deposits may build up on the
Honeycomb Cooling Media and restrict air flow. Draining the
water tank and refilling with fresh water at least once a week
will help reduce mineral deposits. If mineral deposits remain
on the Honeycomb Cooling Media, the media should be
removed and washed under fresh water. The media should
be cleaned every two months or sooner, depending on your
needs.
For best results allow the Honeycomb Cooling Media to dry
after each use by turning off the cool function 15 minutes
before turning the unit off.
t
t
t
t
t
Honeycomb
Cooling Media
Rear Frame
Rear Grill
Carbon Dust
Filter
Figure 1:
Remove all the screws from the Rear Grill.
Carefully push the left and right side of the rear grill and
pull out from the cooler.
Pull out the Carbon Dust Filter* and clean with water as
needed.
To release the Honeycomb Media pull out the Rear
Frame and slide the Honeycomb out of the frame.
Replace or clean media with water and a damp cloth as
needed.
WARNING: DO NOT operate the Air Cooler when the
Rear Grill or Rear Frame is removed from the Air Cooler,
or if there is a loose-fitting Rear Grill or Rear Frame.
Doing so can cause serious injury or dangerous
electrical shock.
1.
2.
3.
4.
5.
Removing the Carbon Dust Filter*/ Honeycomb Cooling Media:
Screws
Push
Push
*Applicable for models with Carbon Dust Filter only.
EN 4
Refill the water tank to deactivate the alarm in cooling mode. First switch OFF the unit and unplug from
the power outlet. Fill the water tank with water above the minimum water level mark. Plug in and switch
ON again.
To deactivate the alarm and continue using the unit as a fan (without evaporative cooling), switch the
unit OFF and then ON again. The Low Water Alarm will not activate in Fan only mode. The Low Water
Alarm will sound again if the COOL function is activated while the water tank is still empty.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Honeywell CO25AE wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info