END-OF-SEASON CARE AND STORAGE
When the humidifier will not be used for at least one week, or it is the end of the season, fol-
low the WEEKLY CARE AND CLEANING instructions in this manual.
If it is the end of the season, remove and discard any accessories from the humidifier.
Dry the humidifier completely before storing. Do not store with water inside the Base, Heating
Chamber or Water Tank.
Pack unit in original carton and store in a cool, dry location.
REASSEMBLE HUMIDIFIER
1.
Place Removable Tray over heating element. Push Locking Tab toward back of unit so Removable
Tray Lift Tab locks in place.
2.
Align Cooling Chamber Tab over Removable Tray. Push Locking Tab toward back of unit so
Cooling Chamber Tab locks into place beside Removable Tray Tab.
3.
Replace Water Tank on Base.
4.
Humidifier is ready to use. See Operating Instructions.
WEEKLY CARE AND CLEANING (Continued from previous page)
TROUBLESHOOTING
Solution
Plug unit in
Check circuits, fuses, test outlet
Fill Water Tank
Place on a level surface
Follow Cleaning Instructions
on previous pages
Rinse thoroughly with
clean water
Refill Water Tank
Follow Reset Procedure
Check Water Tank for leaks; contact
Consumer Relations if necessary
Tighten Tank Cap
Decrease mist output to low
setting and/or open door to
the room
If your Humidifier is not working properly, refer to the following:
Problem
Power Knob is set to “On”
and green light around
Power Knob is off
Little or no mist is produced
Reset Light illuminated
Water overflows
from Reservoir
Condensation forms around
humidifier or on windows
Possible Cause
Unit not plugged in
No power at outlet
No water in Water Tank
Unit is not level
Mineral deposits on Heating
Element or Removable Tray
Water Tank was washed
with detergent
Water Tank is empty
Unit not reset after refill
Water Tank may be leaking
Tank Cap is not tight
Mist intensity is set too
high for room size or
pre-existing humidity level
NOTE: Failure to keep this unit clean from mineral deposits normally contained in any water
supply will affect the efficiency of operation of this unit. Customer failure to follow these
instructions may void the warranty.
Instructions for Scale Removal (continued)
5. Fill Heating Chamber with 1 cup undiluted white vinegar. Vinegar should completely cover
Heating Element.
Place Removable Tray over Heating Element. Push Locking Tab towards back of the unit so
Removable Tray Tab locks in place.
Vinegar solution will loosen mineral buildup (scale) on Heating Element and bottom of Cooling
Chamber as they soak.
6. Soak Heating Element in vinegar solution for 15-20 minutes then gently scrub with a soft
brush to remove mineral deposits. Do not use hard brushes, steel wool or other hard abrasives
on the heating element. Doing so will damage the heating element.
Rinse Base and Removable Tray with water until smell of vinegar is gone.
CAUTION: Do not immerse base in water.
7. Wipe Cooling Chamber, Medicine Cup and Removable Tray with a little vinegar and clean cloth
if not already cleaned in dishwasher.
Step 7
Step 6
Step 5
Instructions for Disinfecting
Follow Steps 1-4 in Scale Removal Instructions in previous section.
For Step 5: While humidifier is disassembled, add 1 tsp of bleach to 1 gallon (3.8L) of water
and fill Water Tank with this solution. Replace Tank Cap. Swish solution around in Water Tank.
If not cleaning Removable Tray, Mist Chimney and Medicine Cup in dishwasher, use some of
the bleach solution to wipe these components clean.
Empty tank and rinse all components with water until smell of bleach is gone.
NOTE: Using more than 1 tsp of bleach per gallon (3.8L) of water may result in damage to
your humidifier.
See steps 6-7 in Scale Removal Instructions in previous section to complete Disinfecting process.
NOTE: Do not mix vinegar and bleach solutions together. Scale Removal and Disinfecting must
be done separately.
Step 5
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Honeywell HWM705 Series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info