817769
96
Zoom out
Zoom in
Vorherige Seite
1/98
Nächste Seite
TECHNICAL INFORMATION 3
Efficiency Decleration 2016/426
II2E+3+ II2H3+ II2H3B/P
G20/G25 20/25mbar 2E+ G20 20mbar 2H G20 20mbar 2H
G30/G31 28-30/37mbar 3+ G30/G31 28-30/37mbar 3+ G30/G31 30/30mbar 3B/P
Countries BE,FR CY,CZ,GB,GR,IE,IT,PT,SI,ES,TR,CH BG,HR,DK,EE,FI,LV,LT,NO,RO,SK,SE,CZ,SI,TR
Gas Categories
II2H3B/P II2EK3B/P II2HS3B/P II2E3B/P II2E3B/P
G20 20mbar 2H G20 20mbar 2E G20 20mbar 2H G20 20mbar 2E G20 20mbar 2E
G25.3 25mbar 2K G25.1 25mbar 2S
G30/G31 30/30mbar 3B/P G30/G31 30/30mbar 3B/P
Countries AT,CH NL HU PL DE
Gas Categories
G30/G31 50/50mbar 3B/P
AUX SR R DC 4 kW
- 60% 55.1% 54.3%
MEDIUM %56.4
UH60MF - BIG REAR (L1)
SINGLE BURNER EFFICIENCY
AUX SR R DC 4.2 kW
- 60% 55.1% 54.3%
MEDIUM %56.4
UH60MF - BIG FRONT (L2)
SINGLE BURNER EFFICIENCY
AUX SR R DC 5 kW
- 60% 57.6% 54.3%
MEDIUM %57.4
UH60MF - DIAMOND (L3)
SINGLE BURNER EFFICIENCY
AUX SR R (Left) R (Right) DC 5 kW
- 56% 54% 54% 57.6%
UH75MF - Central (L4)
SINGLE BURNER EFFICIENCY
MEDIUM %55.4
AUX SR SR R DC 5 kW
- 56% 56% 54% 57.6%
UH75MF - 4+1 (L5)
SINGLE BURNER EFFICIENCY
MEDIUM %55.4
TABLE FRONTAL UH60MF / UH75MF
G20 G20 G25.1 G25.3 G30/G31 G30/G31 G30/G31
20 mbar 25 mbar 25 mbar 25 mbar 28-30 mbar 37 mbar 50 mbar
Injector NG Injector NG Injector NG Injector NG Injector LPG Injector LPG Injector LPG
Max - Min Max - Min Max - Min Max - Min Max - Min Max - Min Max - Min
AUX 1 0,3
72X
(1kW-0.3kW)
70X
(1kW-0.3kW)
74F1
(1kW-0.3kW)
72F1
(1kW-0.3kW)
50
(73g/h-22g/h)
46
(73g/h-25g/h)
46H2
(73g/h-29g/h)
AUX 1,2 kW 1,2 0,3
75F4
(1.2kW-0.3kW)
75X
(1.2kW-0.3kW)
80F1
(1.2kW-0.3kW)
78F1
(1.2kW-0.3kW)
55
(87g/h-22g/h)
53
(87g/h-25g/h)
48H2
(87g/h-29g/h)
SR 1,75 0,6
97Z
(1.75kW-0.6kW)
91Z
(1.75kW-0.6kW)
98Y
(1.75kW-0.6kW)
102F3
(1.75kW-0.6kW)
65
(127g/h-36g/h)
61
(127g/h-40g/h)
58M
(127g/h-44g/h)
R 2,7 1
109Y
(2.7kW-1kW)
110F3
(2.7kW-1kW)
120F2
(2.7kW-1kW)
115F2
(2.7kW-1kW)
80
(196g/h-58g/h)
78
(196g/h-62g/h)
73S
(196g/h-69g/h)
DC 3,8 kW MONO
116 mm burner
NG 3,8 - LPG 3,65
1.8
148H3
(3.8kW-1.8kW)
140H3
(3.8kW-1.8kW)
150F3
(3.8kW-1.8kW)
143F3
(3.8kW-1.8kW)
97
(265g/h-131g/h)
91
(265g/h-138g/h)
75F4
(265g/h-145g/h)
DC 4 kW MONO
116 mm burner
NG 4 - LPG 3,65 1.8
155H1
(4kW-1.8kW)
145H3
(4kW-1.8kW)
154F3
(4kW-1.8W)
146F3
(4kW-1.8kW)
97
(265g/h-131g/h)
94
(265g/h-138g/h)
75F4
(265g/h-145g/h)
DC 4 kW MONO
125 mm burner
4 2,4
151H3
(4kW-2.4kW)
145H3
(4kW-2.4kW)
150F3
(4kW-2.4kW)
146F3
(4kW-2.4kW)
100
(286g/h-160g/h)
94
(286g/h-167g/h)
78F4
(286g/h-175g/h)
DC 4,2 kW MONO NG 4,2 - LPG 4 2,4
153H3
(4,2kW-2.4kW)
148H3
(4,2kW-2.4kW)
154F3
(4,2kW-2.4kW)
148F3
(4,2kW-2.4kW)
100
(286g/h-160g/h)
94
(286g/h-167g/h)
78 F4
(286g/h-175g/h)
DC 5 kW MONO NG 5 - LPG 4.6 2,4
166S4
(5kW-2.4kW)
160H3
(5kW-2.4kW)
168F3
(5kW-2.4kW)
162F3
(5kW-2.4kW)
107
(334g/h-160g/h)
100
(334g/h-167g/h)
95 type 6
(334g/h-175g/h)
Gas Type
Gas Pressure
Burners
Max (kW)
Min (kW)
AUX 1.2 kW SR R DC 3.8 kW
60% 60% 55,9% 52,8%
UH60MF - BIG REAR (L6)
SINGLE BURNER EFFICIENCY
57,2%
AUX 1.2 kW SR
SR (Right)
R DC 4 kW
57,1% 57,1% 60% 54,3% 52,8%
UH75MF - Central (L7)
SINGLE BURNER EFFICIENCY
56,3%
96

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hoover HAHG7 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info