511137
5
Zoom out
Zoom in
Vorherige Seite
1/66
Nächste Seite
3
GB
To access the exhaust filter:
Unlock the exhaust filter door by rotate the door along arrow indicated. 1. 19
Remove the filter pack from recess. 2. [20]
Gently tap and wash the blue Hepa filter unit. Do not use hot water or detergents. Remove 3.
excess water from the filter and leave to dry fully before re-using. [21]
Reassemble filter pack once fully dry and refit to the cleaner. Close the door along arrow 4.
indication.
IMPORTANT: Do not use the product without the filter pack fitted.
NOTE: Ensure the carry handle is at its down position before opening the filter door.
Cleaning the Airvolution separation unit
This cleaner uses the Airvolution separation system, unique to Hoover. If necessary the
Airvolution separation unit can be removed from the dust container and cleaned.
Remove dust container from the cleaner by releasing the container carry handle to detach 1.
the dust container from the main cleaner and pull upward to remove. [15]
Place the bin on a flat surface and unclip the clips from either side of the dust container. 2.
[22]
Using the bin handle lift the bin upper section containing the separation unit from the 3.
lower section. [23]
Use a cloth to remove excessive dust from the separation unit’s surface. 4. [24]
Reassemble the bin upper section. Push clips back to fully close the bin. 5. [25]
Refit the dustbin to the cleaner. To lock in place push the container carry handle down 6.
until the latch connects with the main body of the cleaner. Once correctly retained the
carry handle will sits flush with the top of the cleaner.
Removing a blockage
Check if the dust container is full. If so refer to ‘Emptying the dust container.1.
If the dust container is empty but suction is still low:2.
Do the filters need cleaning? If so refer to ‘Cleaning the washable filters.A.
Check if there is any other blockage in the system - Use a rod or pole to remove any B.
blockage from the extension tube or flexible hose.
Check if pre-motor filter is fitted and filter door is closed.C.
Check if the separation unit needs to be cleaned. Refer to ‘Cleaning the separation D.
unit’.
USER CHECKLIST
IMPORTANT INFORMATION
Should you have a problem with the product, complete this simple user checklist before calling
your local Hoover service.
Is there a working electricity supply to the cleaner? Please check with another electrical •
appliance.
Is the dust container over-filled? Please refer to ‘Cleaner Maintenance.•
Is the filter blocked? Please refer to ‘Cleaner Maintenance’.•
Is the hose or nozzle blocked? Please refer to ‘Removing a blockage from the system. Has the •
cleaner overheated? If so, it will take approximately 30 minutes to automatically reset.
Hoover spares and Consumables
Always replace parts with genuine Hoover spares. These are available from your local Hoover
dealer or direct from Hoover. When ordering parts always quote your model number.
Hepa Pre-Motor Filter: S104 - 35600990•
Hepa Exhaust Filter: T101 - 35600991•
Professional Fibre Hose: D112 - 35600984•
Carpet & Floor Nozzle: G114 - 35600995•
Parquet Caresse Nozzle: G111 - 35600986•
Miniturbo Nozzle Allergen Remover with Silver Ion Technology: J42 - 35600987•
Hoover Service
Should you require service at any time, please contact your local Hoover Service Office.
Quality, Safety and the Environment
Safety
Although safety certification of electrical appliances is not required by law in the UK, Hoover
believe that independent approval is the best way of demonstrating safety in design and
manufacture. The British Electrotechnical Approvals Board (BEAB), the independent UK
national authority for the safety of domestic electrical appliances, ensures that European
safety standards are met and maintained throughout the production life of an appliance. All
appliances that pass the requirements are permitted to carry the BEAB mark of safety.
Xarion_Green__1-4_union.indd 3 03/09/2009 14.22.54
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hoover Xarion Greenway wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info