The Ground Fault Circuit Interrupter (GFCI) is a safety device that is
designed to detect as little as 5 milliamps (±1mA) of electrical current
leakage to ground. Watkins Manufacturing Corporation recommends
that the GFCI be tested prior to each use to ensure it is functioning
correctly. With the spa connected to the power supply, push the "Test"
button. The spa should stop operating and the GFCI power indicator
will go out. Wait 30 seconds and then reset the GFCI by pushing the
Reset button. The GFCI power indicator will turn on, restoring power
to the spa. If the interrupter does not perform in this manner, it is an
indication of an electrical malfunction and the possibility of an electric
shock. Disconnect the plug from the receptacle until the fault has been
identified and corrected.
IMPORTANT: Failure to wait 30 seconds before resetting the GFCI
may cause the spa’s Power indicator (on the control panel) to blink. If
this occurs, repeat the GFCI test procedure.
Never use the GFCI as a means to disconnect power to the spa
(always unplug it). If the GFCI is tripped while the
spa is plugged in, and a power outage occurs,
when power returns the GFCI will automatically
reset and power will flow to the spa.
115 VOLT OPERATION
(60Hz ONLY)
The spa must be connected to a dedicated 115
volt, 20 amp, GFCI protected, grounded circuit.
The term “dedicated” means the electrical circuit
is not being used or shared for any other electrical items (patio lights,
appliances, garage circuits, etc.). If the spa is connected to a non-
dedicated circuit, overloading will result in “nuisance tripping” at the
main panel. This requires frequent resetting of the breaker switch at
the house electrical breaker panel and introduces the possibility of
damage or failure of spa equipment. The dedicated circuit must be
properly wired; that is, it must have a 20-amp GFCI circuit breaker in
the house breaker panel, #12 AWG or larger wire (including the ground
wire) and the correct polarity throughout the circuit.
NEVER CONNECT THE SPA TO AN
EXTENSION CORD!
A pressure wire connector
is provided on the exterior
surface of the control box,
inside the spa. This is to
permit the connection of a
ground bonding wire between
this point and any metal
equipment, enclosures,
reinforced concrete pad, pipe,
or conduit within 5 feet of
the spa (if needed to comply
with local building code
requirements). The bonding
wire must be at least a
#10-AWG solid copper wire.
Bond the spa to all exposed
metal equipment or fixtures,
handrails, and concrete pad
per N.E.C. Article 680 and all
local codes.
INSTALLATION INSTRUCTIONS
All 115 volt HOT SPRING spa models come equipped with
approximately 15 feet of useable power cord (this is the maximum
length allowed by Underwriters Laboratory and the National Electric
Code). When the spa is installed, the power cord will come out of the
System Ground Terminal
GRD
IMPORTANT!
THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER
WILL VARY BETWEEN MANUFACTURERS. CONNECTING THE HOT WIRE TO THE
NEUTRAL TERMINAL WILL CAUSE IRREVERSIBLE DAMAGE TO THE CONTROL BOX.
** Refer to NEC 250-122 (table)
*PROVIDED WITH HOT TUB.
IMPORTANT: ALL WIRING SHOULD BE COPPER.
NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Hot Spring PRODIGY - H wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.