68
WideSide® Sensitivity
(Advanced: with WideSide® transducer)
WideSide® Sensitivity adjusts the sensitivity of the WideSide® beam. Increasing the
sensitivity will display additional weak returns and decreasing the sensitivity will display
few weak returns. A WideSide® transducer must be attached to the 700 Series™ Fishing
System. The WideSide® Sensitivity menu choice is available when Transducer Select is
set to WideSide® (see Sonar Menu Tab: Transducer Select) and User Mode is set to
Advanced (see Setup Menu Tab: User Mode).
NOTE: The WideSide® Sensitivity requires the purchase of the WideSide® transducer. You can
visit our website at www.humminbird.com to order this accessory online or contact our
Customer Resource Center at 1-800-633-1468.
NOTE: WideSide® Sensitivity is particularly useful for adjusting the sensitivity of the 455 kHz
sonar returns in the WideSide® View. The 455 kHz sensitivity can be adjusted without
affecting the sensitivity of the other sonar frequencies.
To change the WideSide® Sensitivity setting:
1. Make sure you have selected WideSide® Transducer and Advanced Mode and
that the WideSide® transducer is connected, then highlight WideSide®
Sensitivity on the Sonar Main Menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the WideSide®
Sensitivity. (-10 to +10, Default = 0)
67
455 kHz Balance
(Advanced, with QuadraBeam™ Transducer)
455 kHz Balance adjusts the sensitivity of the 455 kHz beam. Increasing the sensitivity
will display additional weak returns and decreasing the sensitivity will display fewer
weak returns. A QuadraBeam™ transducer must be attached to the 700 Series™ Fishing
System. The 455 kHz Balance menu choice is available when Transducer Select is set to
QuadraBeam™ (see Sonar Menu Tab: Transducer Select) and User Mode is set to
Advanced (see Setup Menu Tab: User Mode).
NOTE: The 455 kHz Balance requires the purchase of the QuadraBeam™ transducer. You can
visit our website at www.humminbird.com to order this accessory online or contact our
Customer Resource Center at 1-800-633-1468.
NOTE: 455 kHz Balance is particularly useful for adjusting the sensitivity of the 455 kHz sonar
returns in the Side Beam View. The 455 kHz sensitivity can be adjusted without affecting the
sensitivity of the 200 kHz returns shown in the 200 kHz sonar window.
T
o change the 455 kHz Balance setting:
1. Make sure you have selected QuadraBeam
TM
Transducer and Advanced Mode,
then highlight 455kHz Balance on the Sonar Main Menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the 455 kHz Balance.
(-10 to +10, Default = 0)