43
InstallatIon
Legislation
Installation of your HWAM woodburning stove must always comply with local building regulations. It is
a good idea to consult your local chimney sweep before installing, since he will be the one to sweep the
chimney and stove.
Room requirements
There must be a constant supply of fresh air to the room in which the stove is to be installed. A window that
opens or an adjustable air vent should be sufficient, but it is also possible to connect the stove to a HWAM
combustion air system. The air inlet/grating must be placed so that they do not become blocked.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Load-bearing capacity of floor
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand
the weight of the stove and the chimney. The weight of the chimney should be calculated according to
its dimensions and height.
Weight of the stove
HWAM 3510: 93 kg HWAM 3510, rounded sides: 102 kg
HWAM 3510, soap stone top: 115 kg HWAM 3510, soap stone: 150 kg
HWAM 3520: 108 kg HWAM 3520, rounded sides: 114 kg
HWAM 3520, soap stone top: 127 kg HWAM 3520, soap stone: 164 kg
HWAM 3530: 114 kg HWAM 3530, rounded sides: 124 kg
HWAM 3530, soap stone top: 136 kg HWAM 3530, soap stone: 184 kg
Distance to inflammable materials
Your HWAM woodburning stove should always be installed on a non-combustible hearth. If it is installed
on a wooden floor or similar, the floor must be covered with a non-combustible material.
HWAM 3510, HWAM 3520, HWAM 3530 (Drawing A)
1. Recommended for brick wall 10 cm
1. For inflammable back wall 10 cm
2. For inflammable side wall 20 cm
1.To inflammable wall,corner installation 10 cm*
3. Distance to furnishings in front 80 cm
*All dimensions in connection with corner installation are only recommendations. Contact your chimney sweep for a
clarification.
Remember to pay attention to any regulations concerning the required distance between
the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the automatics system. The stove can be
mounted with wall fittings on a brick wall; however, this means that the stove must be taken down when
the automatics system is to be serviced.