cm above the ridge. If the chimney is placed at side walls, the top of the chimney should always be higher
than the ridge or the tallest point of the roof. Always be aware of any national and/or local regulations
applying to thatched roofs and the location of the chimneys.
The stove requires a draft of at least 12 Pa.
The chimney must have a minimum clearing of Ø 150 mm. The chimney must be provided with an
easily accessible cleaning door. The chimney and flue duct must be of flue class T400 and be CE marked.
Furthermore, it must have obtained the classification of G in soot fire testing. The required distance to
combustible material must be complied with in accordance with the brand label. Ask your HWAM retailer
for further information.
Connection to chimney
All the stoves have both rear and top smoke outlet that can be connected to an approved steel chimney on
top or directly out at the rear to a chimney.
Make sure that the chimney is tight and that no false draft is caused around neither the cover plate, in
connection with a covered smoke outlet, nor the cleanout door and pipe connections. Please note that
bent and/or horizontal smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of smoke flue (Drawing B and C)
B: Top smoke outlet
C: Rear smoke outlet
Steel chimney (9).
Flue gas elbow (10). Fits into smoke flue socket.
Brick-built jamb of flue (11).
Built-in pipe sleeve (12). Fits smoke flue.
Wall rosette (13). Covers disruption to wall around pipe sleeve.
Joint (14). Sealed with packing material.
Smoke outlets (15) of the HWAM stove.
Smoke flue regulating damper (16).
Soot door (17).
Fitting the loose parts
Before the stove is installed, you must ensure that all loose parts are fitted correctly. Check that all insula-
tion plates of the combustion chamber have been properly placed, i.e. that the bottom plate is horizontal
and that the side plates are vertical and reach all the way up to the steel sides of the combustion chamber
and down to the bottom plate.
Vertical cross-section of the stoves (Drawing B, C and D):
The smoke shelf (5). To be placed on top of the steel rail and on the holders in the sides
Two-piece smoke defector plate (6). Each half is hung on the hooks located beneath the top plate. The two
halves join in the holders (7a) behind the air pipe. Once the stove has been installed, remove the safety
fittings for transportation (7b) from the two hooks
Rear plate (2a), covering HWAM
®
Autopilot™. This must always be mounted if the stove is placed
next to a combustible wall
Chimney
The chimney is the “engine” of the stove and it is crucial for the functioning of the woodburning stove.
The chimney draft provides a partial vacuum in the stove. This vacuum removes the smoke from the stove,
sucks air through the dampers for the so-called glass pane rinse which keeps the glass free of soot, and
sucks in air through both primary and secondary dampers for the combustion.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Hwam 4240 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Hwam 4240

Hwam 4240 Bedienungsanleitung - Deutsch - 20 seiten

Hwam 4240 Bedienungsanleitung - Holländisch - 20 seiten

Hwam 4240 Bedienungsanleitung - Französisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info