23
4
REPEATER OPERATION
■ Auto repeater (U.S.A. version only)
The USA version automatically activate the repeater settings
(DUP– or DUP+ and tone encoder ON/OFF) when the operating
frequency falls within the general repeater output frequency
range and deactivate them when outside of the range.
D Setting the auto repeater function ON/OFF
q Push [PWR] to turn power OFF.
w
While pushing
[SET ]
, turn power ON to enter initial
set mode.
e Push [SET ] several times until the “RPT” display
appears as shown above right.
r Rotate [DIAL] to turn the auto repeater function to “R1,”
“R2” or OFF.
• “R1”: auto repeater is ON, tone encoder is OFF.
• “R2”: auto repeater is ON, tone encoder is ON.
t Push [PWR] to exit initial set mode.
D Frequency range and offset direction
LOCK
S
E
T
ANM
MONI
DUP
LOW
T
-
SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL
PRIO
AO
BUSY
MUTE
NAR
MID
LOW
LOCK
S
E
T
ANM
MONI
DUP
LOW
T
-
SCAN
TONE
PRIO
M/CALL
SCAN
V/MHz
DIGITAL
PRIO
AO
BUSY
MUTE
NAR
MID
LOW
Auto repeater function is
turned OFF.
Auto repeater function is ON,
tone encoder is ON.