670163
156
Zoom out
Zoom in
Vorherige Seite
1/173
Nächste Seite
19
CONTROL COMMAND
19-3
Remote control (CI-V) information (Continued)
Cmd. Sub cmd. Data Description
00 p. 19-8 Send frequency data (transceive)
01 p. 19-8 Send mode data (transceive)
02 p. 19-8 Read band edge frequencies
03 p. 19-8 Read operating frequency
04 p. 19-8 Read operating mode
05 p. 19-8 Set operating frequency
06 p. 19-8 Operating mode selection for transceive
07 Select the VFO mode
00 Select VFO A
01 Select VFO B
A0 Equalize VFO A and VFO B
B0 Exchange VFO A and VFO B
08 Select the Memory mode
0001 to
0109
Select the Memory channel
*(0001=M-CH01, 0099=M-CH99)
0100 Select program scan edge channel P1
0101 Select program scan edge channel P2
09 Memory write
0A Memory copy to VFO
0B Memory clear
0E 00 Scan stop
01 Programmed/memory scan start
02 Programmed scan start
03 F scan start
12 Fine programmed scan start
13
Fine F scan start
22 Memory scan start
23 Select memory scan start
A1
Select F scan span ±5 kHz
A2
Select F scan span ±10 kHz
A3
Select F scan span ±20 kHz
A4
Select F scan span ±50 kHz
A5
Select F scan span ±100 kHz
A6
Select F scan span ±500 kHz
A7
Select F scan span ±1 MHz
B0 Set as non-select channel
B1 Set as select channel
( The previously set number by CI-V is set
after turning power ON, or “1” is selected if
no selection is performed.)
01 to 03 Set as select channel
*(01=SEL1, 02=SEL2, 03=SEL3)
B2 00 to 03 Set for select memory scan
*(00=ALL, 01=SEL1, 02=SEL2, 03=SEL3)
D0 Set Scan resume OFF
D3 Set Scan resume ON
0F 00/01 Read Split setting (00=OFF, 01=ON)
00 Turn the split function OFF
01 Turn the split function ON
10* 00 Send/read the tuning step OFF
01 Send/read the 100 Hz tuning step
02 Send/read the 1 kHz tuning step
03 Send/read the 5 kHz tuning step
04 Send/read the 9 kHz tuning step
05 Send/read the 10 kHz tuning step
06 Send/read the 12.5 kHz tuning step
07 Send/read the 20 kHz tuning step
08 Send/read the 25 kHz tuning step
11* 00/20 Send/read Attenuator
*(00=OFF, 20=20dB ON)
13 00 Speech all data with voice synthesizer
01 Speech the operating frequency and S meter
level by voice synthesizer
02 Speech the operating mode by voice
synthesizer
14* 01 0000 to
0255
Send/read the AF level
*(0000=min. to 0255=max.)
02 0000 to
0255
Send/read the RF gain level
*(0000=min. to 0255=max.)
03 0000 to
0255
Send/read the squelch level
*(0000=min. to 0255=max.)
Cmd. Sub cmd. Data Description
06 0000 to
0255
Send/read the NR level
*(0000=0% to 0255=100%)
07 0000 to
0255
Send/read inner [TWIN PBT] position
*
( 0000=max. CCW, 0128=center, 0255=max.
CW)
08 0000 to
0255
Send/read outer [TWIN PBT] position
*( 0000=max. CCW, 0128=center, 0255=max.
CW)
09 0000 to
0255
Send/read CW pitch
*( 0000=300 Hz, 0128=600 Hz, 0255=900 Hz;
5 Hz steps)
0A 0000 to
0255
Send/read [RF PWR] position
*(0000=max. CCW, 0255=max. CW)
0B 0000 to
0255
Send/read [MIC] position
*(0000=max. CCW, 0255=max. CW)
0C 0000 to
0255
Send/read [KEY SPEED] level
*(0000=6wpm, 0255=48wpm)
0D 0000 to
0255
Send/read [NOTCH] position
*
( 0000=max. CCW, 0128=center, 0255=max.
CW)
0E 0000 to
0255
Send/read the COMP level
*(0000=0 to 0255=10)
0F 0000 to
0255
Send/read the Break-IN Delay setting
*(0000=2.0d to 0255=13.0d)
12 0000 to
0255
Send/read NB level
*(0000=0% to 0255=100%)
15 0000 to
0255
Send/read the Monitor gain
*(0000=0% to 0255=100%)
16 0000 to
0255
Send/read the VOX gain
*(0000=0% to 0255=100%)
17 0000 to
0255
Send/read the Anti VOX gain
*(0000=0% to 0255=100%)
19 0000 to
0255
Send/read BRIGHT level
*(0000=0%, 0255=100%)
15 01 00/01 Read noise or S-meter squelch status
*(squelch close)
02 0000 to
0255
Read S-meter level
*(0000=S0, 0120=S9, 0241=S9+60dB)
05 00/01 Read various squelch function’s status
*(squelch closed)
11 0000 to
0255
Read PO meter level
*(0000=0%, 0143=50%, 213=100%)
12 0000 to
0255
Read SWR meter level
*( 0000=SWR1.0, 0048=SWR1.5,
0080=SWR2.0, 0120=SWR3.0)
13 0000 to
0255
Read ALC meter level
*(0000=Min. to 0120=Max.)
14 0000 to
0255
Read COMP meter level
*(0000=0 dB, 0130=15 dB,0241=30 dB)
15 0000 to
0255
Read Vd meter level
*(0000=0 V, 0013=10 V, 0241=16 V)
16 0000 to
0255
Read Id meter level
*(0000=0, 0097=10, 0146=15, 0241=25)
16* 02 00 to 02 Preamp
( 00=OFF, 01=Preamp 1 ON, 02=Preamp 2 ON)
12 00 to 03
AGC
*(00=OFF, 01= FAST, 02= MID, 03=SLOW)
22 00 to 01 Noise blanker *(00=OFF, 01=ON)
40 00 to 01 Noise reduction *(00=OFF, 01=ON)
41 00 to 01 Auto notch function *(00=OFF, 01=ON)
42 00 to 01 Repeater tone *(00=OFF, 01=ON)
43 00 to 01 Tone squelch *(00=OFF, 01=ON)
44 00 to 01 Speech compressor *(00=OFF, 01=ON)
45 00 to 01 Monitor function *(00=OFF, 01=ON)
46 00 to 01 VOX function *(00=OFF, 01=ON)
47 00 to 02 BK-IN function
*( 00=BK-IN OFF, 01=Semi BK-IN ON,
02=Full BK-IN ON)
48 00 to 01 Manual notch function *(00=OFF, 01=ON)
4F 00 to 01 Twin Peak Filter *(00=OFF, 01=ON)
Can be turned ON only when Mark and Shift
are set to 2125 Hz and 170 Hz, respectively.
D Command table
156

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

icom-ic-7300

Suche zurücksetzen

  • hallo
    gibt es eine deutsche beschreibung des ic-7300 Eingereicht am 28-5-2024 15:35

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Icom IC-7300 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info